PubMed Health⌕ Search

PubMed · 14716618

Arrhythmia database for algorithm testing: surface leads plus intracardiac leads for validation.

Abstract

Ann Arbor Electrogram Libraries (AAEL) is a database of over 500 electrocardiographic recordings made during clinical electrophysiology studies over a period of 15 years. These data are used by university researchers and cardiac device research and development laboratories to develop and test arrhythmia detection algorithms. The AAEL library is in use by all major implantable cardioverter defibrillator manufacturers as well as several Automated External Defibrillator developers. In 1996, the USFDA Center for Devices and Radiological Health licensed a portion of Volumes I for proposed device testing. The data consist of 7 channels of signals: surface leads I, III, V1, an intra-atrial high right atrium (bipolar), an intra-atrial high right atrium (unipolar), an intraventricular right ventricular apex (bipolar), and intraventricular right ventricular apex (unipolar) from the distal catheter electrode. Data were recorded under careful engineering quality control continuously (30 min-1.5 hr) on FM magnetic tape at a tape speed of 3.75 in/s after signal amplification at a filter setting of 1-500 Hz. Amplifier gain and filter settings were held constant during the entire recording procedure and a 1 mV calibration signal was entered as a reference at the time of recording. All patient recordings contain a baseline sinus rhythm, and subsequently induced ventricular tachycardia and/or ventricular fibrillation, or less frequently, supraventricular tachycardia, atrial tachycardia, and/or atrial fibrillation. Data are typically made available in digitized format (1,000 Hz); digital or FM recordings are also available. AAEL recordings are the only widespread intracardiac test files in the industry.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Janice M Jenkins, Richard E Jenkins. 2003. Arrhythmia database for algorithm testing: surface leads plus intracardiac leads for validation.. https://doi.org/10.1016/j.jelectrocard.2003.09.041. https://pubmed.health/record/pubmed%3A14716618/arrhythmia-database-for-algorithm-testing-surface-leads-plus-intracardiac-leads-for-validation

Citations retain the original authors and DOI and include this site’s record URL. If this discovery service contributed to your research, you can also cite PubMed Health by Indiciae: BibTeX · RIS.

KEEP EXPLORING

Related citations

Safety of nerve conduction studies in patients with implanted cardiac devices.

Patients with implanted cardiac devices and their physicians may defer important electrodiagnostic testing because of anxiety about potential negative effects on the device. To determine the safety of routine nerve conduction studies (NCS) in this population, 10 patients with permanent dual-chamber pacemakers of various types and five patients with implanted cardiac defibrillators (ICD) underwent nerve stimulation at sites commonly used during NCS. The implanted cardiac device was interrogated before and after the study and there was continuous monitoring of the surface electrocardiogram (ECG) and atrial and ventricular electrograms. Electrical impulses generated during routine NCS were never detected by the sensing amplifier and did not affect the programmed settings of the implanted cardiac device. We conclude that routine NCS is safe in patients with implanted cardiac pacemakers with bipolar sensing configurations and defibrillators.

Arrhythmias, Cardiac↗

[Pulmonary diseases and heart function].

The most severe cardiac sequel to lung disease is the load on the right ventricle due to pulmonary hypertension with the development of a cor pulmonale. This is characterized by hypertrophy and/or dilatation of the right ventricle because of a primary impairment of lung function and/or lung structure. The most important pathomechanisms for the development of pulmonary hypertension are vessel obliteration, mechanical lesions, primary vascular or extra-vascular inflammation and hypoxic vasoconstriction. Chronic obstructive pulmonary disease (COPD) is one of the most important reasons for chronic cor pulmonale. A further very common reason is obstructive sleep apnea syndrome, especially if combined with a COPD. In this case, the prevalence of cor pulmonale can reach 80%. The development of a chronic cor pulmonale is the most striking negative prognostic factor for these patients. Only 30% of COPD patients with cor pulmonale survive longer than 5 years, and only early detection of the disturbances to respiration which might potentially lead to cor pulmonale and their subsequent therapy are able to improve the patient's prognosis. Furthermore, pulmonary diseases may also have an impact on the left heart side in terms of an impairment of left heart function or by inducing severe arrhythmias . Thus, lung diseases may have both a significant impact on right and left heart performance.

Arrhythmias, Cardiac↗