Finite element models predict cancellous apparent modulus when tissue modulus is scaled from specimen CT-attenuation.

Abstract

High-resolution architecture-based finite element models are commonly used for characterizing the mechanical behavior of cancellous bone. The vast majority of studies use homogeneous material properties to model trabecular tissue. The objectives of this study were to demonstrate that inhomogeneous finite element models that account for microcomputed tomography-measured tissue modulus variability more accurately predict the apparent stiffness of cancellous bone than homogeneous models, and to examine the sensitivity of an inhomogeneous model to the degree of tissue property variability. We tested five different material cases in finite element models of ten cancellous cubes in simulated uniaxial compression. Three of these cases were inhomogeneous and two were homogeneous. Four of these cases were unique to each specimen, and the remaining case had the same tissue modulus for all specimens. Results from all simulations were compared with measured elastic moduli from previous experiments. Tissue modulus variability for the most accurate of the three inhomogeneous models was then artificially increased to simulate the effects of non-linear CT-attenuation-modulus relationships. Uniqueness of individual models was more critical for model accuracy than level of inhomogeneity. Both homogeneous and inhomogeneous models that were unique to each specimen had at least 8% greater explanatory power for apparent modulus than models that applied the same material properties to all specimens. The explanatory power for apparent modulus of models with a tissue modulus coefficient of variation (COV) range of 21-31% was 13% greater than homogeneous models (COV=0). The results of this study indicate that inhomogenous finite element models that have tissue moduli unique to each specimen more accurately predict the elastic behavior of cancellous cubic specimens than models that have common tissue moduli between all specimens.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Benjamin C Bourne, Marjolein C H van der Meulen. 2004. Finite element models predict cancellous apparent modulus when tissue modulus is scaled from specimen CT-attenuation.. https://doi.org/10.1016/j.jbiomech.2003.10.002

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

A simple non invasive computerized method for the assessment of bone repair within osteoconductive porous bioceramic grafts.

Single energy X-ray imaging, due to its low cost and flexibility, is one of the most used and common technique to assess bone state and bone remodeling over time. Standardized X-ray images are needed to compare sets of radiographs for semi-quantitative analyses of tissue remodeling. However, useful mathematical modeling for the analysis of high level radiographic images are not easily available. In order to propose a useful evaluation tool to a wide clinical scenario, we present an innovative calibration algorithm for a semi-quantitative analysis of non-standardized digitized X-ray images. For calibration on a unique standardization scale, three time invariant regions (ROI) of radiographs were selected and analyzed. The accuracy of the normalization method for X-ray films was successfully validated by using an aluminum step wedge for routine X-ray exposures as tool to standardize serial radiographs (Pearson correlation test: R(2) = 0.96). This method was applied to investigate the progression of the new bone deposition within ceramic scaffolds used as osteoconductive substitute in large bone defects taking advantage of a large animal model. This innovative image-processing algorithm allowed the identification and semi-quantification of the bone matrix deposited within the implant. The osteo-integration at the bone-implant interface was also investigated. A progressively increasing bone tissue deposition within the porous bioceramic implant and a progressive osteo-integration was observed during the 12 months of the trial.

Absorptiometry, Photon↗

Combined LIBD and XAFS investigation of the formation and structure of Zr(IV) colloids.

The solubility of Zr(OH)4(am)--in other words hydrated Zr(IV) oxyhydroxide--is determined by means of coulometric titration (CT), and colloids are detected by laser-induced breakdown when the solubility limit is exceeded. Our results at pH 3-8 demonstrate that the solubility of Zr(OH)4(am) is several orders of magnitude higher than reported classical solubility data for acidic solutions, determined from undersaturation with a less soluble microcrystalline Zr(IV) oxide precipitate. Analysis of extended X-ray absorption fine structure (EXAFS) data shows that the microcrystalline colloids in a 0.1 mol l(-1) Zr aqueous solution at pH 0.2 contain tetrameric units, similar to those present in the structure of ZrOCl2.8H2O. Characterization of the CT solutions by means of EXAFS shows that oligomeric species form as the solubility limit is approached. The current lack of data on equilibrium constants for polynuclear hydroxide complexes prohibits the use of a realistic speciation model to describe the solubility of pH-dependent Zr(OH)4(am). However, the solubility curve is obtained using the mononuclear hydrolysis constants estimated in the present paper, along with the solubility constant (log K'sp=-49.9+/-0.5 in 0.5 mol l(-1) NaCl; log K degrees(sp)=-53.1+/-0.5 at I=0).

Absorptiometry, Photon↗

Three-dimensional modeling of EXAFS spectral mixtures by combining Monte Carlo simulations and target transformation factor analysis.

We have developed a new method for the three-dimensional modeling of extended X-ray absorption fine structure (EXAFS) spectra which enables the extraction of the local structure of aqueous metal complexes from spectral mixtures of several components. The new method combines two techniques: Monte Carlo simulation and target transformation factor analysis (TFA). Monte Carlo simulation is used to create random arrangements between the X-ray absorbing metal ion and the ligand atoms, and to calculate the theoretical EXAFS spectrum of each arrangement. The theoretical EXAFS spectrum is then introduced as test spectrum in the TFA procedure, to test whether or not the test spectrum is likely to be a component of the spectral mixtures. This coupled procedure is repeated until the error in the test spectrum is minimized. The new method can thus be used to isolate and refine the structure of complexes from spectral mixtures and to determine their relative concentrations, solely on the basis of an estimate of a ligand structure. The performance of the proposed method is validated using uranium Liii-edge EXAFS spectra of binary mixtures of two uranium(VI) 3,4-dihydroxybenzoic acid complexes.

Absorptiometry, Photon↗