Initial experience with catheter probe US when using a multibending endoscope.

Abstract

BACKGROUND: High-frequency catheter probe US provides detailed images when the scanning plane is perpendicular to the area of interest and the latter is within the focal zone. A multibending endoscope has been developed that has two bending sections that can be deflected independently. The aim of this study was to determine whether this new endoscope enhances high-frequency catheter probe US. METHODS: High-frequency catheter probe US was performed with the multibending endoscope in 33 patients with upper-GI lesions. The endoscope was carefully maneuvered until the scanning plane was perpendicular to the area of interest and the target area was within the focal zone of the probe. The effects of deflecting the second bending section on the image and on the rotating elements in the probe were evaluated. RESULTS: For 28 lesions, no improvement was observed with use of both bending sections. However, for 5 lesions, the US image was improved by use of the second bending section. These lesions were located in the stomach on the lesser or greater curve. In no instance did deflection of both bending sections result in uneven rotation of the mechanical elements in the probe. CONCLUSIONS: For certain lesions, US images obtained with a catheter probe can be improved by using an endoscope with a second bending section.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Shigeto Yoshida, Shinji Tanaka, Daisuke Kamino, Madoka Nakao, Shiro Oka, Yasuhiko Kitadai, Norihiko Hayakawa, Ken Haruma, Kazuaki Chayama. 2004. Initial experience with catheter probe US when using a multibending endoscope.. https://doi.org/10.1016/s0016-5107(04)01270-2

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Immune heparin-induced thrombocytopenia resulting from preceding exposure to heparin catheter flushes.

Immune heparin-induced thrombocytopenia (HIT) is a life-threatening adverse effect of heparin. It can result from any type of heparin exposure and by any route of administration; however only a few cases are reported after exposures to small quantities of heparin from catheter flushes. The major clinical problem associated with HIT is thrombosis. Early detection and institution of alternative, non-heparin anticoagulation are important. We report a patient with HIT associated with use of therapeutic-dose unfractionated heparin in whom immune sensitization to heparin was triggered by two 500-unit exposure to UFH associated with intravascular catheter flushing for antineoplastic chemotherapy in a patient with colon adenocarcinoma.

Catheterization↗