PubMed Health⌕ Search

PubMed · 15623891

Radionuclide biokinetics database (RBDATA-EULEP): an update.

Abstract

The main activity of the RBDATA-EULEP project is the development of an electronic database of information on the biokinetics of radionuclides after intake by inhalation, ingestion or injection. It consists of linked tables of publications and experiments, with details and comments on the materials, procedures and results. By March 2004 it contained information on more than 1600 experiments from 600 publications. It will be extended and Internet access will also be provided.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

M R Bailey, E Ansoborlo, V Chazel, P Fritsch, A Hodgson, W G Kreyling, B Le Gall, D Newton, F Paquet, N Stradling, M Svartengren, D M Taylor, S Wenman-Bateson. 2004. Radionuclide biokinetics database (RBDATA-EULEP): an update.. https://doi.org/10.1093/rpd%2Fnch098

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Dosimetric and microdosimetric study of contrast-enhanced radiotherapy with kilovolt x-rays.

Kilovolt x-rays are clearly suboptimal compared to MV photon beams for radiotherapy of deep-seated tumours because of the increased attenuation in tissue, causing a rapid dose fall-off. This picture could change drastically when tumours can be labelled with contrast medium, containing high atomic number elements. This causes a significant dose enhancement to the tumour by exploiting the high cross sections for the photo-electric effect for kV x-rays. In this work, we have investigated the dosimetric and microdosimetric characteristics of kV contrast-enhanced radiation therapy (CERT) for different photon energies, contrast-medium concentrations and types (I and Gd). Two idealized patient treatment plans (head and lung) for irradiation with CT-arc beams were calculated. It is shown that the dose enhancement in tumours can be highly significant (up to about sixfold for realistic 80-120 kVp x-ray spectra and an iodine concentration of 50 mg ml-1) but that dose homogeneity in the tumour depends on photon energy, contrast-medium concentration and type, and irradiation scheme. An attempt to optimize the irradiation scheme is discussed. The microdosimetric study of the dose mean lineal energy shows that radiation quality changes in the contrast-medium-labelled region compared to homogeneous tissue are fairly small and limited to 10%. It is concluded that kV-CERT is a promising radiotherapy technique, provided contrast medium can be delivered reliably to tumours.

Body Burden↗

Absolute and relative dose-surface and dose-volume histograms of the bladder: which one is the most representative for the actual treatment?

The purpose of this study was to quantify to what extent relative and absolute bladder dose-volume and dose-surface histograms of the planning CT scan were representative for the actual treatment. We used data of 17 patients, who each received 11 repeat CT scans and a planning CT scan. The repeat CT scans were matched on the planning CT scan by the bony anatomy. Clinical treatment plans were used to evaluate the impact of bladder filling changes on the four histogram types. The impact was quantified by calculating for this patient group the correlation coefficient between the planning histogram and the treatment histogram. We found that the absolute dose-surface histogram was the most representative one for the actual treatment.

Body Burden↗

Determination of 234U/238U ratio: comparison of multi-collector ICPMS and ICP-QMS for water, hair and nails samples, and comparison with alpha-spectrometry for water samples.

The (234)U/(238)U ratio in water, hair and nails samples was determined by multi-collector inductively coupled plasma mass spectrometry (MC-ICPMS) and inductively coupled plasma quadrupole mass spectrometry (ICP-QMS) and by alpha-spectrometry for the water samples only. A correlation of 0.99 was found between the two ICPMS methods and of 0.98 with alpha-spectrometry. The range of activity ratios was between 0.9 and 2.6 according to the MC-ICPMS measurements. The reproducibility of both ICPMS techniques was better than 4% for water samples containing 1 mug l(-1) of uranium and a (234)U/(238)U atom ratio of 54.9 x 10(-6). Sample preparation for the ICPMS consisted of dilution of water samples containing >10 microg l(-1) of uranium and measurement time was approximately 1 min, while alpha-spectrometry involved pre-concentration and separation of the uranium and counting times of 1,000 min.

Body Burden↗