Visualizing three-dimensional flow with simulated streamlines and three-dimensional phase-contrast MR imaging.

Abstract

Three-dimensional (3D) velocity maps acquired with 3D phase-contrast magnetic resonance (MR) imaging contain information regarding complex motions that occur during imaging. A technique called simulated streamlines, which facilitates the display and comprehension of these velocity data, is presented. Single or multiple seed points may be identified within blood vessels of interest and tracked through the velocity field. The resulting trajectories are combined with a 3D MR angiogram and displayed with 3D volume visualization software. Mathematical analysis highlights potential applications and pitfalls of the technique, which was implemented both in phantoms and in vivo with excellent results. For example, single streamlines reveal helical flow patterns in aneurysms, and multiple streamlines seeded in the common carotid artery reveal branch filling-time relationships and slow filling of the carotid bulb. The technique is helpful in understanding these complex flow patterns.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

S Napel, D H Lee, R Frayne, B K Rutt. Visualizing three-dimensional flow with simulated streamlines and three-dimensional phase-contrast MR imaging.. https://doi.org/10.1002/jmri.1880020206

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Effects of anterior communicating artery diameter on cerebral hemodynamics in internal carotid artery disease. A model study.

BACKGROUND: Collateral circulatory pathways are considered the primary determinant of cerebral hemodynamics in patients with obstructive lesions of the internal carotid arteries (ICaAs). However, the hemodynamic effects of the diameter of the anterior communicating artery (ACoA) have never been assessed quantitatively in humans. METHODS AND RESULTS: Two different mathematical models were used to simulate changes affecting blood pressures and flows in cerebral arteries as a function of ACoA diameter and ICaA stenoses or occlusions. Small changes in ACoA diameter were found to have marked hemodynamic effects when they occurred within the range of 0.4 to 1.6 mm, a situation observed in 80% of the cases. Outside this range, changes in ACoA diameter had no effect. Simulated pressure drops through a stenotic ICaA were consistent with those observed. They were found to depend on the degrees of the stenoses in both ICaAs and on ACoA diameter according to a simple equation. Pressure reserve in the middle and anterior cerebral arteries decreased to below the lower limit of autoregulation, despite a normal mean arterial blood pressure, when the arteries were distal to a unique 70% ICaA stenosis associated with a small-diameter ACoA or to a 50% ICaA stenosis associated with a contralateral ICaA occlusion and a large-diameter ACoA. Above these thresholds, the circle of Willis allowed for an almost complete global cerebral blood flow compensation that involved all the afferent and communicating vessels. CONCLUSIONS: ACoA diameter strongly modulates the effects of ICaA lesions on cerebral hemodynamics. Some proposals for endarterectomy indications can be derived from our study.

Blood Flow Velocity