PubMed Health⌕ Search

PubMed · 16172882

The detection of formaldehyde in textiles using interdigitated microelectrode array diffusion layer titration with electrogenerated hypobromite.

Abstract

An interdigitated microelectrode array (IDA) was applied to the determination of formaldehyde released from textiles produced in industry. The proposed method is based on formaldehyde reaction with hypobromite which is formed in weakly basic media by control current electrooxidation of bromide on the generator segment of the IDA array. The unreacted hypobromite diffuses through the gap between individually polarisable IDA segments and it is amperometrically detected on the collector segment of the IDA. The efficiency of this nonconvective transfer process in the absence of formaldehyde was substantially higher (78%) in comparison with that when using the rotating ring disc electrode. The influence of the added formaldehyde on the transfer process can be utilised to develop a simple and sensitive analytical procedure for formaldehyde detection with a detection limit of 4 x 10(-6) mol dm(-3).

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Peter Tomcík, Pavlína Jencusová, Monika Krajcíková, Dusan Bustin, Roman Brescher. 2005-11-05. The detection of formaldehyde in textiles using interdigitated microelectrode array diffusion layer titration with electrogenerated hypobromite.. https://doi.org/10.1007/s00216-005-0055-0

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

A competitive molecular recognition study: syntheses and analysis of supramolecular assemblies of 3,5-dihydroxybenzoic acid and its bromo derivative with some N-donor compounds.

A molecular recognition study of 3,5-dihydroxybenzoic acid (1) and its bromo derivative 4-bromo-3,5-dihydroxybenzoic acid (2) with the N-donor compounds 1,2-bis(4-pyridyl)ethene (bpyee), 1,2-bis(4-pyridyl)ethane (bpyea), and 4,4'-bipyridine (bpy) is reported. Thus, the syntheses and structural analysis of molecular adducts 1 a-1 c (1 with bpyee, bpyea, and bpy, respectively) and 2 a-2 c (2 with bpyee, bpyea, and bpy, respectively) are discussed. In all these adducts, recognition between the constituents is established through either O--H...N and/or O--H...N/C--H...O pairwise hydrogen bonds. In all the adducts both OH and COOH functional groups available on 1 and 2 interact with the N-donor compounds, except in 2 a, in which only COOH (COO-) is involved in the recognition process. The COOH moieties in 1 a, 1 b, and 2 b form only single O--H...N hydrogen bonds, whereas in 1 c and 2 c, they form pairwise O--H...N/C--H...O hydrogen bonds. In addition, subtle differences in the recognition patterns resulted in the formation of cyclic networks of different dimensions. In fact, only 1 c forms a four-molecule cyclic moiety, as was already documented in the literature for this kind of assemblies. All complexes have been characterized by single-crystal X-ray diffraction. The supramolecular architectures are quite elegant and simple, with stacking of sheets in all adducts, but a rather complex network with a threefold interpenetration pattern was found in 2 c.

Bromine Compounds↗

Hyphenation of ultra performance liquid chromatography (UPLC) with inductively coupled plasma mass spectrometry (ICP-MS) for fast analysis of bromine containing preservatives.

Ultra performance liquid chromatography (UPLC) was coupled to inductively coupled plasma mass spectrometry (ICP-MS) for fast analysis of three bromine-containing preservatives, monitoring the 79Br and 81Br isotopes simultaneously. Due to the efficiency of the 1.7 microm column packing material, the resolution of the test substances was only slightly affected when the linear flow velocity was increased from 0.5 to 1.9 mm s(-1). However, the sensitivity of ICP-MS detection decreased when the linear flow velocity was increased from 0.5 to 1.9 mm s(-1). Analytical figures of merit were determined at an intermediate and at a high linear velocity. The precision was better than 2.2% R.S.D. and regression analysis showed that a linear response was achieved at both flow rates (R2 > 0.9993, n = 36). The analysis time was less than 4.5 min at a flow rate of 50 microL min(-1) and limits of detection and quantification were better than 3.3 and 11 microg BrL(-1), respectively. The analysis time was reduced to 2.7 min when the flow rate was increased to 90 microL min(-1) and limits of detection and quantification were better than 20 and 65 microg BrL(-1), respectively. The method was applied for quantitative analysis of bromine-containing preservatives in commercially available cosmetic products.

Bromine Compounds↗