PubMed Health⌕ Search

PubMed · 16175274

Microfluidic system for dielectrophoretic separation based on a trapezoidal electrode array.

Abstract

This paper presents a novel microfluidic device for dielectrophoretic separation based on a trapezoidal electrode array (TEA). In this method, particles with different dielectric properties are separated by the device composed of the TEA for the dielectrophoretic deflection of particles under negative dielectrophoresis (DEP) and poly(dimethylsiloxane)(PDMS) microfluidic channel with a sinuous and expanded region. Polystyrene microparticles are exposed to an electric field generated from the TEA in the microfluidic channel and are dielectrophoretically focused to make all of them line up to one sidewall. When these particles arrive at the region of another TEA for dielectrophoretic separation, they are separated having different positions along the perpendicular direction to the fluid flow due to their different dielectrophoretic velocities. To evaluate the separation process and performance, both the effect of the flow rate on dielectrophoretic focusing and the influence of the number of trapezoidal electrodes on dielectrophoretic separation are investigated. Now that this method utilizes the TEA as a source of negative DEP, non-specific particle adhering to the electrode surface can be prevented; conventional separation approaches depending on the positive DEP force suffer from this problem. In addition, since various particle types are continuously separated, this method can be easily applicable to the separation and analysis of various dielectric particles with high particle recovery and selectivity.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Sungyoung Choi, Je-Kyun Park. 2005-08-02. Microfluidic system for dielectrophoretic separation based on a trapezoidal electrode array.. https://doi.org/10.1039/b505088j

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Generation of complex, static solution gradients in microfluidic channels.

A microfluidic device is used to generate a complex gradient of diffusible molecules in a static solution. The gradient is precise and steady both in space and in time. This device, made from poly(dimethylsiloxane), consists of three layers. The molecules in reservoirs on the top layer diffuse through the flat middle layer of hydrogel and reach an equilibrium distribution. Microfluidic channels on the bottom layer that are in close contact with the hydrogel contain free solution that has concentration gradients based on the gradient in the gel. The gradient profile in the channel can be designed to have an arbitrary form (within the range of the existing gradient in the hydrogel) by controlling the local direction of the channel at each point.

Dimethylpolysiloxanes↗

Application of a static solid-phase microextraction procedure combined with liquid-liquid extraction to determine poly(dimethyl)siloxane-water partition coefficients for selected polychlorinated biphenyls.

A static solid-phase microextraction (SPME) procedure combined with liquid-liquid extraction (LLE) was used to determine the poly(dimethyl)siloxane (PDMS)-water partition coefficients (K(f)) for selected polychlorinated biphenyl congeners (PCBs), including PCB 1, 15, 28, 47, 101, 153, 180, 202, 206, and 209. The accuracy for the measurements of analyte concentrations in the aqueous phase was ensured with a one-to-one recovery correction strategy employing one 13C-labeled PCB congener as a surrogate standard for each unlabeled PCB counterpart. The effects of coating thickness (7, 30, and 100 microm) and sample volume (130 mL and 2 L) on the K(f) values were examined experimentally and confirmed with paired t-tests. Significant dependence of K(f) values on coating thickness was found for a few heavily chlorinated congeners only, and was tentatively attributed to the use of the inaccurate effective coating volumes and the structural variation with these PDMS coatings. In addition, no significant differences in the log K(f) values of all analytes except for PCB 206 were found between the sample sizes of 130 mL and 2 L for both the 7- and 100-microm coatings. Overall, K(f) values obtained with 2-L sample containers were consistently higher than those reported in the literature, which is attributable to the selection of appropriate equilibrium times for SPME and direct measurements of aqueous analyte concentrations with LLE in the present study.

Dimethylpolysiloxanes↗

Reliable fabrication method of transferable micron scale metal pattern for poly(dimethylsiloxane) metallization.

We have developed a reliable fabrication method of forming micron scale metal patterns on poly(dimethylsiloxane) (PDMS) using a pattern transfer process. A metal stack layer consisting of Au-Ti-Au layers, providing a weak but reliable adhesion, was deposited on a silicon wafer. The metal stack layer was then transferred to a PDMS substrate using serial and selective etching. We demonstrate that features as small as 2 microm were reliably transferred on to the PDMS substrate for use as interconnects and electrodes for biosensors and flexible electronics application.

Dimethylpolysiloxanes↗