Application of a static solid-phase microextraction procedure combined with liquid-liquid extraction to determine poly(dimethyl)siloxane-water partition coefficients for selected polychlorinated biphenyls.

Abstract

A static solid-phase microextraction (SPME) procedure combined with liquid-liquid extraction (LLE) was used to determine the poly(dimethyl)siloxane (PDMS)-water partition coefficients (K(f)) for selected polychlorinated biphenyl congeners (PCBs), including PCB 1, 15, 28, 47, 101, 153, 180, 202, 206, and 209. The accuracy for the measurements of analyte concentrations in the aqueous phase was ensured with a one-to-one recovery correction strategy employing one 13C-labeled PCB congener as a surrogate standard for each unlabeled PCB counterpart. The effects of coating thickness (7, 30, and 100 microm) and sample volume (130 mL and 2 L) on the K(f) values were examined experimentally and confirmed with paired t-tests. Significant dependence of K(f) values on coating thickness was found for a few heavily chlorinated congeners only, and was tentatively attributed to the use of the inaccurate effective coating volumes and the structural variation with these PDMS coatings. In addition, no significant differences in the log K(f) values of all analytes except for PCB 206 were found between the sample sizes of 130 mL and 2 L for both the 7- and 100-microm coatings. Overall, K(f) values obtained with 2-L sample containers were consistently higher than those reported in the literature, which is attributable to the selection of appropriate equilibrium times for SPME and direct measurements of aqueous analyte concentrations with LLE in the present study.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Ze-Yu Yang, Eddy Y Zeng, Huan Xia, Ji-Zhong Wang, Bi-Xian Mai, Keith A Maruya. 2006-03-31. Application of a static solid-phase microextraction procedure combined with liquid-liquid extraction to determine poly(dimethyl)siloxane-water partition coefficients for selected polychlorinated biphenyls.. https://doi.org/10.1016/j.chroma.2006.03.029

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Study of on-line monitoring of lactate based on optical fibre sensor and in-channel mixing mechanism.

A PDMS-based microfluidic device with integrated optical fibres was developed for online monitoring of lactate. The detection is based on the optical adsorption of the colour solution formed by in-channel mixing of sample and reagent solutions. Computational Fluid Dynamics (CFD) simulation and kinetic study of the colour development were conducted to determine the minimum channel length and optimum residential time for homogenous mixing and maximum optical adsorption respectively. The system was proved to be able to detect lactate with good linearity (R(2)=0.98), response time of about 130 s and estimated limitation of detection (LOD) of 0.52 mM (about 47 mg/L), which is sufficient for a general online lactate detection. Due to the miniaturization of sensing system and micro-scale mixing, higher detection sensitivity (0.15 V/mM) can be realized than the mixing in lab-scale equipments (0.08 V/mM).

Dimethylpolysiloxanes↗

Glass-fiber reinforced poly(acrylate)-based sorptive materials for the enrichment of organic micropollutants from aqueous samples.

A novel and simple approach to sorptive materials for the extraction of organic compounds from environmental samples is presented. It entails the use of glass fiber fabric strips coated with a customized poly(acrylate) (PA) formulation as extraction medium. Analytes were enriched by means of shaking of the PA strip in the sample and then subsequently thermally desorbed and analyzed by GC-MS. The performance of the sorptive materials was evaluated by the enrichment of compounds with different polarities (phenols, hexachlorobenzene and hexachlorocyclohexanes) from water samples. Parameters that affect the extraction process such as pH, ionic strength of the solvent, mixing mechanism, extraction time and desorption conditions were investigated. The extraction abilities of the PA extraction medium were compared with that of commercially available poly(dimethylsiloxane) (PDMS) Twisters. The results revealed that the new material shows higher affinity for phenolic compounds presumably due to the presence of polar groups. The partition coefficients for the PA strips estimated in this work were up to 15 times higher than for the PDMS Twister, resulting in higher recoveries and lower detection limits. The method was applied for the quantification of the aforementioned compounds in contaminated surface water samples from Bitterfeld (Germany). Using both PA strips and PDMS Twisters, good agreement of the extraction data was achieved.

Dimethylpolysiloxanes↗