PubMed Health⌕ Search

PubMed · 1623041

Automated solid models from serial section images.

Abstract

A new method for creating unambiguous and complete boundary representation solid models with a hybrid polygonal/nonuniform rational B spline representation was developed and tested using computed tomography scans of the wrist. Polygon surface approximation was applied to a sequence of parallel planar outlines of individual bone elements in the wrist. An automated technique for the transformation of edge contours into solid models was implemented. This was performed using a custom batch file command sequence generator coupled to a commercially available mechanical computer-aided design and engineering software system known as I-DEAS (Structural Dynamics Research Corporation, Milford, OH). This transformation software allows the use of biomedical scan slice data with a solid modeler.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

C M Ho, M W Vannier, S J Bresina. 1992. Automated solid models from serial section images.. https://doi.org/10.1007/bf03167837

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Carpal anomalies.

Explore the source record for details and available documents.

Carpal Bones↗

Diagnostic strategy for suspected scaphoid fractures in the presence of other fractures in the carpal region.

Bone scintigraphy will identify up to 25% of occult scaphoid bone fractures after negative scaphoid X-rays. Consequently, it deserves a place in the diagnostic process of suspected scaphoid fractures. However, the role of bone scintigraphy is less clear if scaphoid X-rays show other fractures in the carpal region. We analysed 111 consecutive patients with a suspected scaphoid fracture on physical examination. Scaphoid X-rays revealed 61 fractures. Fifty-five patients had scaphoid fractures only and six patients had other fractures in the carpal region but no scaphoid fracture. In 50 cases, no bone injury was seen on these X-rays. In three out of the six patients with other fractures in the carpal region, bone scintigraphy revealed four occult concomitant fractures: one scaphoid, one scaphoid and trapezial and one capitate fracture. In conclusion, bone scintigraphy is required when scaphoid X-rays do not confirm a suspected scaphoid fracture, even in the presence of other fractures in the carpal region.

Carpal Bones↗

Intra-individual comparison between open and 2-portal endoscopic release in clinically matched bilateral carpal syndrome.

Based upon bilateral carpal tunnel syndrome (CTS) we undertook a prospective randomised intra-individual comparison between open (OR) and 2-portal endoscopic release (2-PER) to establish if there is any demonstrable advantage in undertaking either technique in a 1 year follow-up. Ten patients with bilateral CTS were enrolled in this study and underwent a 2-PER on the one and an OR with two minimised incisions on the contralateral hand. Both hands were examined pre- and postoperatively after 2, 4, 6 and 12 weeks and after 6 and 12 months, respectively. Preoperatively both hands revealed statistically no significant differences in all the parameters recorded. Comparing both techniques no significant differences could be detected in the follow-up period. Nevertheless, both techniques showed significant improvements in the severity of symptoms and pain, in sensory nerve testing and in electro-diagnostic parameters, when comparing pre- with postoperative data after 1 year. The endoscopic approach revealed no distinct advantages over the open technique not only in the late but also in the early postoperative follow-up period when performing intra-individual comparison. Considering the higher complication rate and costs when performing 2-PER the OR with two minimised incisions seems to be a good alternative in order to keep the recovery period as short as possible.

Carpal Bones↗