PubMed Health⌕ Search

PubMed · 16448865

What makes a champion? Explaining variation in human athletic performance.

Abstract

Variation in human athletic performance is determined by a complex interaction of socio-cultural, psychological, and proximate physiological factors. Human physiological trait variance has both an environmental and genetic basis, although the classic gene-environment dichotomy is clearly too simplistic to understand the full range of variation for most proximate determinants of athletic performance, e.g., body composition. In other words, gene and environment interact, not just over the short term, but also over the lifetime of an individual with permanent effects on the adult phenotype. To further complicate matters, gene and environment may also be correlated. That is, genetically gifted individuals may be identified as children and begin training pulmonary, cardiovascular, and muscle systems at an early critical age. This review covers evidence in support of a genetic basis to human athletic performance, with some emphasis on the recent explosion of candidate gene studies. In addition, the review covers environmental influences on athletic performance with an emphasis on irreversible environmental effects, i.e., developmental effects that may accrue during critical periods of development either before conception (epigenetic effects), during fetal life (fetal programming), or during childhood and adolescence. Throughout, we emphasize the importance of gene-environment interaction (G x E) as a means of understanding variation in human physiological performance and we promote studies that integrate genomics with developmental biology.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Tom D Brutsaert, Esteban J Parra. 2006-01-30. What makes a champion? Explaining variation in human athletic performance.. https://doi.org/10.1016/j.resp.2005.12.013

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Diffusion tensor magnetic resonance imaging mapping the fiber architecture remodeling in human myocardium after infarction: correlation with viability and wall motion.

BACKGROUND: Diffusion tensor magnetic resonance imaging (DT-MRI) provides a means for nondestructive characterization of myocardial architecture. We used DT-MRI to investigate changes in direction-dependent water diffusivity to reflect alterations in tissue integrity (trace apparent diffusion coefficients [ADCs] and fractional anisotropy [FA]), as well as indicators of remodeling of fiber helix angles, in patients after myocardial infarction. METHODS AND RESULTS: Thirty-seven patients (35 men, 2 women; median age, 59) after acute myocardial infarction (median interval from onset, 26 days) were enrolled. DT-MRI was performed at the midventricular level to measure trace ADC, FA, and helix angles of myofibers. Helix angles were grouped into left-handed helical fibers, circumferential fibers, and right-handed helical fibers. Measurements were correlated with viability and regional wall motion assessed by contrast-delay-enhancement and cine MRI, respectively. The infarct zone showed significantly increased trace ADC and decreased FA than the remote zone. The percentage of left-handed helical fibers increased from the remote zone (mean +/- SD, 13.3 +/- 5.8%) to the adjacent zone (19.2 +/- 9.7%) and infarct zone (25.8 +/- 18.4%) (MANOVA, P = 0.004). The percentage of right-handed helical fibers decreased from the remote zone (35.0 +/- 9.0%) to the adjacent zone (25.5 +/- 11.5%) and infarct zone (15.9 +/- 9.2%) (P < 0.001). Multiple linear regression showed that the percentage of left-handed helical fibers of the infarct zone was the strongest correlate of infarct size and predictor of ejection fraction. CONCLUSIONS: In vivo DT-MRI of postinfarct myocardium revealed a significant increase in trace ADC and a decrease in FA, indicating altered tissue integrity. The redistribution of fiber architecture correlated with infarct size and left ventricular function. This technique may help us understand structural correlates of functional remodeling after infarction.

Cardiovascular Physiological Phenomena↗

Development of a mathematical model of the human circulatory system.

A mathematical lumped parameter model of the human circulatory system (HCS) has been developed to complement in vitro testing of ventricular assist devices. Components included in this model represent the major parts of the systemic HCS loop, with all component parameters based on physiological data available in the literature. Two model configurations are presented in this paper, the first featuring elements with purely linear constitutive relations, and the second featuring nonlinear constitutive relations for the larger vessels. Three different aortic compliance functions are presented, and a pressure-dependent venous flow resistance is used to simulate venous collapse. The mathematical model produces reasonable systemic pressure and flow behaviour, and graphs of this data are included.

Cardiovascular Physiological Phenomena↗