PubMed Health⌕ Search

PubMed · 16572215

Reversible thermo-responsive sieving matrix for oligonucleotide separation.

Abstract

A reversible thermo-responsive gel system, consisting of Pluronic copolymer mixture of F87 and F127, has been used to successfully carry out the separation of oligonucleotides, for the first time, by microchip-based capillary electrophoresis. Pluronic triblock copolymers F87 (E(61)P(40)E(61)) and F127 (E(99)P(69)E(99)), with E, P, and subscript denoting oxyethylene, oxypropylene, and segment length respectively, have a unique temperature dependent viscosity-adjustable property and a dynamic coating ability in aqueous solution, including 1 x TBE buffer. The mixture solution has a reversible thermo-responsive property and its sol-gel transition temperature can be adjusted ranging from about 17 degrees C to 38 degrees C by varying the relative weight ratio of F87 and F127 at an optimized concentration of approximately 30% (w/v) for oligonucleotide separations. Oligonucleotide sizing markers ranging from 8 to 32 base could be successfully separated in a 1.5 cm long separation channel by the mixture solution in its gel-like state. A 30% (w/v) with a F87/F127 weight ratio of 1 ratio 2 which has a "sol-gel" transition point of about 26 degrees C shows the best sieving ability. The sieving ability of the mixture solution was further confirmed in an Agilent Bioanalyzer 2100 system. Fast separation of oligonucleotides has been achieved within 40 s with one base resolution.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Jun Zhang, Marcus Gassmann, Weidong He, Fen Wan, Benjamin Chu. 2006-03-02. Reversible thermo-responsive sieving matrix for oligonucleotide separation.. https://doi.org/10.1039/b515557f

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Ultrasonic standing wave manipulation technology integrated into a dielectrophoretic chip.

Several cell-based biological applications in microfluidic systems require simultaneous high-throughput and individual handling of cells or other bioparticles. Available chip-based tools for contactless manipulation are designed for either high-precision handling of individual particles, or high-throughput handling of ensembles of particles. In order to simultaneously perform both, we have combined two manipulation technologies based on ultrasonic standing waves (USWs) and dielectrophoresis (DEP) in a microfluidic chip. The principle is based on the competition between long-range ultrasonic forces, short-range dielectrophoretic forces and viscous drag forces from the fluid flow. The ultrasound is coupled into the microchannel resonator by an external transducer with a refractive element placed on top of the chip, thereby allowing transmission light microscopy to continuously monitor the biological process. The DEP manipulation is generated by an electric field between co-planar microelectrodes placed on the bottom surface of the fluid channel. We demonstrate flexible and gentle elementary manipulation functions by the use of USWs and linear or curved DEP deflector elements that can be used in high-throughput biotechnology applications of individual cells.

Electrophoresis, Microchip↗

Rapid on-column analysis of glucosamine and its mutarotation by microchip capillary electrophoresis.

A novel electrophoretic microchip method for analyzing alpha- and beta-d-glucosamine and their interconversion in solution is presented. d-Glucosamine is labeled with fluorescamine and analyzed by capillary electrophoresis in under 2 min revealing its pH-dependent mutarotation between the alpha- and beta-anomers. The forward interconversion rates for the labeled sugars, based on an iterative analysis of the plateau heights between the peaks, are 0.72+/-0.09, 1.3+/-0.1, and 2.2+/-0.3 x 10(-3)s(-1) at pH 8.99, 9.51 and 10.01, respectively. In a separate experiment, the mutarotation of the unlabeled alpha-d-anomer was followed; the relative intensities of the alpha- and beta-peaks as a function of reaction time at pH 9.51 give a forward rate constant of 0.6+/-0.1 x 10(-3)s(-1). These results demonstrate that fast microchip separations, previously exploited for amine, amino acid, and nucleobase analysis, can also be used to analyze amino sugars and their mutarotation.

Electrophoresis, Microchip↗

Dielectrophoresis field flow fractionation of single-walled carbon nanotubes.

We report a study on Dielectrophoresis Field Flow Fractionation of Single-Wall Carbon Nanotubes (SWNTs). SWNTs, individually suspended in 1% SDBS solution, were separated by type when they passed a dielectrophoresis field flow fractionation device where 1 MHz AC voltage was supplied and the field strength was well below 1 V per mum. Furthermore, we uniquely observed enrichment of semiconductive SWNTs based on their band gap. In addition to Raman spectrum, UV-vis absorption and NIR fluorescence spectra were used for solution samples for characterization.

Electrophoresis, Microchip↗