Time efficiency of CT colonography: 2D vs 3D visualization.

Abstract

We aimed to compare the time efficiency of three visualization methods in CT colonography and to identify the colonic factors influencing the time for interpretation. Twenty CT colonographic examinations were prospectively analysed. Three reading methods were adopted: method 1, primary 2D analysis with the use of virtual endoscopy as problem solver, method 2, primary standard virtual endoscopy with semiautomatic navigation through the colon and use of 2D images as problem solver; method 3, primary virtual endoscopy with automatic navigation and the use of 2D images as problem solver. In method 1, time for 2D analysis ranged between 6 and 18min (mean 12) for evaluation of both supine and prone decubitus with a synchronization method. In method 2, time for 3D manual navigation in supine plus prone ranged between 9 and 24min (mean 17). In method 3, time for automated navigation ranged between 6 and 20min (mean 12) for evaluation of both supine and prone decubitus. A statistically significant difference was found between time efficiency of methods 1 and 2 (p=0.009, t-test, unequal variances). Methods 2 and 3 showed a tendency to significant differences (p=0.054, t-test, unequal variances). Faecal or fluid residuals were reported as major drawbacks in 3D navigations, requiring constant correlation with 2D images; tortuous folds influenced mostly the 2D analysis; diverticula were reported as influencing factor in all three methods. No differences in sensitivity and specificity were observed between the three viewing methods. The 3D semiautomatic navigation method* tended to increase the time for interpretation in almost all cases. There is, in particular, greatest time efficiency for 2D analysis as compared with 3D manual analysis. Two-dimensional and automated 3D navigation reading have comparable time efficiencies in a routine clinical setting.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Emanuele Neri, Francesca Vannozzi, Paola Vagli, Alex Bardine, Carlo Bartolozzi. 2006-05-26. Time efficiency of CT colonography: 2D vs 3D visualization.. https://doi.org/10.1016/j.compmedimag.2006.03.003

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Magnetic resonance colonography vs computed tomography colonography for the diagnosis of colorectal cancer: an indirect comparison.

OBJECTIVE: The primary aim of this study was to use meta-regression techniques to compare the diagnostic accuracy of computed tomography colonography (CTC) and magnetic resonance colonography (MRC), compared with conventional colonoscopy for patients presenting with colorectal cancer (CRC). METHOD: Quantitative meta-analysis was performed using prospective studies reporting comparative data between CTC and MRC individually to conventional colonoscopy. Study quality was assessed and sensitivities, specificities, diagnostic odds ratios (DOR) were calculated. Summary receiver operating characteristic (SROC) curves and sensitivity analysis were utilized. Meta-regression was used to indirectly compare the two modalities following adjustment for patient and study characteristics. RESULTS: Overall sensitivity and specificity for CTC (0.96, 95% CI 0.92-0.99; 1.00, 95% CI 0.99-1.00 respectively) and MRC (0.91, 95% CI 0.79-0.97; 0.98, 95% CI 0.96-0.99 respectively) for the detection of CRC was similar. Meta-regression analysis showed no significant difference in the diagnostic accuracy of both modalities (beta=-0.64, P=0.37 and 95% CI of 0.12-2.39). Both tests showed high area under the SROC curve (CTC=0.99; MRC=0.98), with high DORs (CTC=1461.90, 95% CI 544.89-3922.30; MRC=576.41, 95% CI 135.00-2448.56). Factors that enhanced the overall accuracy of MRC were the use intravenous contrast, faecal tagging and exclusion of low-quality studies. No factors improved diagnostic accuracy from CTC except studies with more than 100 patients (AUC=1.00, DOR=2938.35, 95%CI 701.84-12 302.91). CONCLUSION: This meta-analysis suggested that CTC and MRC have similar diagnostic accuracy for detecting CRC. Study quality, size and intravenous/intra-luminal contrast agents affect diagnostic accuracies. For an exact comparison to be made, studies evaluating CTC, MRC and colonoscopy in the same patient cohort would be necessary.

Colonography, Computed Tomographic↗

Development of a synthetic phantom for the selection of optimal scanning parameters in CAD-CT colonography.

The aim of this paper is to present the development of a synthetic phantom that can be used for the selection of optimal scanning parameters in computed tomography (CT) colonography. In this paper we attempt to evaluate the influence of the main scanning parameters including slice thickness, reconstruction interval, field of view, table speed and radiation dose on the overall performance of a computer aided detection (CAD)-CTC system. From these parameters the radiation dose received a special attention, as the major problem associated with CTC is the patient exposure to significant levels of ionising radiation. To examine the influence of the scanning parameters we performed 51 CT scans where the spread of scanning parameters was divided into seven different protocols. A large number of experimental tests were performed and the results analysed. The results show that automatic polyp detection is feasible even in cases when the CAD-CTC system was applied to low dose CT data acquired with the following protocol: 13 mAs/rotation with collimation of 1.5 mm x 16 mm, slice thickness of 3.0mm, reconstruction interval of 1.5 mm, table speed of 30 mm per rotation. The CT phantom data acquired using this protocol was analysed by an automated CAD-CTC system and the experimental results indicate that our system identified all clinically significant polyps (i.e. larger than 5 mm).

Colonography, Computed Tomographic↗