PubMed Health⌕ Search

PubMed · 16738268

Multidetector computed tomography for acute pulmonary embolism.

Abstract

BACKGROUND: The accuracy of multidetector computed tomographic angiography (CTA) for the diagnosis of acute pulmonary embolism has not been determined conclusively. METHODS: The Prospective Investigation of Pulmonary Embolism Diagnosis II trial was a prospective, multicenter investigation of the accuracy of multidetector CTA alone and combined with venous-phase imaging (CTA-CTV) for the diagnosis of acute pulmonary embolism. We used a composite reference test to confirm or rule out the diagnosis of pulmonary embolism. RESULTS: Among 824 patients with a reference diagnosis and a completed CT study, CTA was inconclusive in 51 because of poor image quality. Excluding such inconclusive studies, the sensitivity of CTA was 83 percent and the specificity was 96 percent. Positive predictive values were 96 percent with a concordantly high or low probability on clinical assessment, 92 percent with an intermediate probability on clinical assessment, and nondiagnostic if clinical probability was discordant. CTA-CTV was inconclusive in 87 of 824 patients because the image quality of either CTA or CTV was poor. The sensitivity of CTA-CTV for pulmonary embolism was 90 percent, and specificity was 95 percent. CTA-CTV was also nondiagnostic with a discordant clinical probability. CONCLUSIONS: In patients with suspected pulmonary embolism, multidetector CTA-CTV has a higher diagnostic sensitivity than does CTA alone, with similar specificity. The predictive value of either CTA or CTA-CTV is high with a concordant clinical assessment, but additional testing is necessary when the clinical probability is inconsistent with the imaging results.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Paul D Stein, Sarah E Fowler, Lawrence R Goodman, Alexander Gottschalk, Charles A Hales, Russell D Hull, Kenneth V Leeper, John Popovich, Deborah A Quinn, Thomas A Sos, H Dirk Sostman, Victor F Tapson, Thomas W Wakefield, John G Weg, Pamela K Woodard, PIOPED II Investigators. 2006-06-01. Multidetector computed tomography for acute pulmonary embolism.. https://doi.org/10.1056/nejmoa052367

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

The effect of acute pain crisis on exhaled nitric oxide levels in children with sickle cell disease.

Exhaled nitric oxide (FE(NO)) has been shown to be decreased in children with sickle cell disease. We sought to evaluate the effect of sickle cell vaso-occlusive crisis (VOC) on FE(NO) levels. We measured FE(NO) levels in 42 children with sickle cell disease, 29 in their baseline health and 13 during an acute VOC. There was no difference in FE(NO) levels between children at baseline (15.12 +/- 9.32 ppb) and those during an acute VOC (15.68 +/- 7.26 ppb; P = 0.794). FE(NO) is not a useful marker of acute VOC in children with sickle cell disease.

Acute Disease↗

[Megadolichobasilar anomaly causing acute deafness with vertigo].

Megadolichobasilar anomaly, a dilatant arteriopathy of the basilar artery attributable to chronic arterial hypertension, can cause cranial nerve compression syndromes of the cerebellopontine angle or infarcts of the vertebrobasilar circulation. In this paper, we report on a patient with known megadolichobasilar anomaly and a partially thrombosed fusiform aneurysm of the basilar artery, who presented with acute-onset vertigo and subsequent deafness due to thromboembolic occlusion of the labyrinthine artery. Because of the vascular origin of the patient's symptoms, his vertigo disappeared over time while the deafness persisted.

Acute Disease↗

Retrieval of a leaflet escaped in a Tri-technologies bileaflet mechanical prosthetic valve.

The escape of the prosthetic heart valve disc is one of the causes of prosthetic dysfunction that requires emergency surgery. The removal of the embolized disc should be carried out because of the risk of a progressive extrusion on the aortic wall. Several imaging techniques can be used for the detection of the missing disc localization. In this report we describe a 32-year-old man who underwent mitral valve replacement with a Tri-technologies bileaflet valve three years ago, and was admitted in cardiogenic shock. Transesophageal echocardiography showed acute-onset massive mitral regurgitation. The patient underwent emergency replacement of the prosthetic valve. Only one of the two leaflets remained in the removed prosthetic valve. The missing leaflet could not be found within the cardiac cavity. The abdominal fluoroscopic study and plain radiography were unable to detect the escaped leaflet. The abdominal computed tomography scan and the ultrasound showed the escaped leaflet in the terminal portion of the aortic bifurcation. To retrieve the embolized disc laparotomy and aortotomy were performed three months later. The escaped leaflet shows a fracture of one of the pivot systems caused by structural failure. This kind of failure mode is usually the result of high stress concentration.

Acute Disease↗