PubMed Health⌕ Search

PubMed · 16806391

Peripheral defocus does not necessarily affect central refractive development.

Abstract

PURPOSE: Recent experiments in monkeys suggest that deprivation, imposed only in the periphery of the visual field, can induce foveal myopia. This raises the hypothesis that peripheral refractive errors imposed by the spectacle lens correction could influence foveal refractive development also in humans. We have tested this hypothesis in chicks. METHODS: Chicks wore either full field spectacle lenses (+6.9 D/-7 D), or lenses with central holes of 4, 6, or 8mm diameter, for 4 days (n=6 for each group). Refractions were measured in the central visual field, and at -45 degrees (temporal) and +45 degrees (nasal), and axial lengths were measured by A-scan ultrasonography. RESULTS: As previously described, full field lenses were largely compensated within 4 days (refraction changes with positive lenses: +4.69+/-1.73 D, negative lenses: -5.98+/-1.78 D, both p<0.001, Dunnett's test, to untreated controls). With holes in the center of the lenses, the central refraction remained emmetropic and there was not even a trend of a shift in refraction (all groups: p>0.5, Dunnetts test). At +/-45 degrees , the lenses were partially compensated despite the 4/6/8mm central holes; positive lenses: +2.63 / +1.44 / +0.43 D, negative lenses: -2.57 / -1.06 / +0.06 D. CONCLUSIONS: There is extensive local compensation of imposed refractive errors in chickens. For the tested hole sizes, peripherally imposed defocus did not influence central refractive development. To alter central refractive development, the unobstructed part in the central visual field may have to be quite small (hole sizes smaller than 4mm, with the lenses at a vertex distance of 2-3mm).

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Ruth Schippert, Frank Schaeffel. 2006-06-27. Peripheral defocus does not necessarily affect central refractive development.. https://doi.org/10.1016/j.visres.2006.05.008

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

A study for accommodating the human crystalline lens by finite element simulation.

This paper constructs two finite element models of human crystalline lens and zonules based on published clinical data. Displacement and pressure were applied to study the mechanism of vision accommodation. The simulation results show that, in Model A, under the pull of the zonules, the thickness of the lens decreased linearly, and the lens diameter increased linearly. The optical power of the lens increased as the zonules displacement increased. Furthermore, the pressure had a remarkable influence on the shape of the lens and the optical power. The lens also became thinner and flatter as the pressure increased. The optical power increased when the pressure increased. In Model B, the lens became thicker and optical power increased as the equatorial zonules stretched. It is basically consistent with Schachar's hypothesis. The outcome of this paper proved that the analytical model presented in this paper can be used in the theoretical study of the accommodation mechanism of the lens.

Accommodation, Ocular↗

Focusing on body sites: the role of spatial attention in action perception.

Humans use the same representations to code self-produced and observed actions. Neurophysiological evidence for this view comes from the discovery of the so-called mirror neurons in premotor cortex of the macaque monkey. These neurons respond when the monkey performs a particular action but also when it observes the same behavior in another individual. In humans, such direct links between perception and action seem to mediate action priming, where a response is facilitated when a similar action is observed. An issue that has not been fully resolved concerns the role of selective attention in these processes. Action priming appears to be an automatic process in the sense that the observed action can be irrelevant to the observer's task and nevertheless prime similar responses. However, it is not known whether attention has to be oriented to the action for these processes to be engaged. It is demonstrated here that spatial attention indeed has to be oriented to the action related body site for action priming to take place. Furthermore, if attention is oriented to the appropriate body site, there need be no visual cues to action for action priming to emerge.

Accommodation, Ocular↗

The axial misalignment between ocular lens and cornea observed by MRI (I)--at fixed accommodative state.

Lens tilt and decentration relative to the corneal axis are two of the factors which cause aberration in human eyes. Although many techniques have been developed to quantitatively measure these factors, however, they are mostly confined in 2D observations. To extend the view from 2D to 3D, MR imaging technique becomes a good candidate due to its capability of 3D-image reconstruction and with fairly good spatial resolution for that purpose. In this study a total of six eyes of six young students at this Institute were examined by using a 1.5T MRI machine incorporating with a commercial 3-in. surface coil at Taipei Veterans General Hospital. From a 45 degrees flipped reflective mirror, the subject could focus to a target at a distance of 60 cm from the eye for MR imaging in monocular vision. Quadric surface models were used to fit cornea and lens surfaces in the post image processes. Tilts of the two lens surfaces and the decentration of lens centre with respect to corneal axis were determined through coordinate transformations. One month later, retest was carried out on five of the six subjects. The results show that the average tilts of anterior and posterior lens surfaces, and lens decentration are 3.7+/-2.5 degrees, 3.3+/-1.4 degrees and 0.11+/-0.07 mm (H), -0.06+/-0.38 mm (V), respectively, for the test; 2.1+/-2.4 degrees, 1.9+/-1.8 degrees and -0.02+/-0.28 mm (H), -0.45+/-0.28 mm (V) for the retest. No statistically significant difference (by Wilcoxon Signed Ranks test) is revealed for the tilts of both lens surfaces (p(phia)=0.375, p(phip)=0.225) and for decentration (p(H)=0.343, p(V)=0.345) between test and retest in this longitudinal observation. The surface shapes of the ocular anterior components do not seem to be unified by only one type but ellipsoid, elliptic paraboloid, hyperboloid and paraboloid are all possible. Changes in shape type in the ocular anterior components were also found when measured in a period of one month.

Accommodation, Ocular↗