Bandwidth-induced errors in parameters used for automated activation time determination during computerized intraoperative cardiac mapping: theoretical limits.

Abstract

Two parameters commonly used when determining the time of local activation during computerized intraoperative cardiac mapping are the time of the peak in bipolar electrograms (BP) and the time of the largest negative slope (LNS) in monopolar electrograms (MP). The dependence of these parameters upon bandwidth was studied. A database of fast MP and BP was compiled from intraoperative recordings collected from epicardial sock arrays in man. Based on 95%, 99% and 99.9% of total signal power, the bandwidths of each response were determined. After removing specified frequencies using the Fourier transform, errors in determining these parameters were computed and characterized with respect to mean square error (MSE), percent power bandwidth and frequency content. The Fourier transform was used to abruptly filter out undesired upper frequencies. Filtering BP at 200 Hz produced a 1-ms shift in the peak in 17.0% of the electrograms, 0.4% of the peaks shifted by 2 ms and none shifted by more than 2 ms. Comparable shifts in the LNS occurred when filtering MP at 400 Hz. Retention of 95% of the power in a BP rarely (0.9%) changed the time of its peak by more than 1 ms. For MP, retention of 99.9% of the power was required for similar performance (3.6%). Thus, although BP have greater signal power in the higher frequencies than MP, a greater bandwidth is required when recording monopolarly in order to preserve the small amount of power necessary to define the time of the LNS with accuracy comparable to determination of the peak in BP.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

C F Pieper, G Lawrie, R Roberts, A Pacifico. 1991. Bandwidth-induced errors in parameters used for automated activation time determination during computerized intraoperative cardiac mapping: theoretical limits.. https://doi.org/10.1111/j.1540-8159.1991.tb05092.x

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

A user-friendly PC-based data acquisition and analysis system for respirometric investigations.

We have developed an easy-to-use computer-based system for recording, displaying, storing and analyzing signals generated by Clark-type oxygen electrodes. A user-friendly interface of Windows-based program BioMed significantly increases the productivity of investigations. It allows to process, control, present and archive the experimental data in real time. A 12-bit analog-to-digital-converter, analog and digital filters, a possibility to zoom the obtained respiratory curves and calculation of the respiration rates by a linear regression method increase the resolution of the estimated oxygen consumption rates. The new system enables to register even small changes, such as 3-5 ngatoms O/min, in respiration rates of biological objects -- enzymes, mitochondria and permeabilized muscle fibers. The system has been developed and is regularly used for the respirometric investigations at the Laboratory of Biochemistry, Institute for Biomedical Research, Kaunas University of Medicine.

Analog-Digital Conversion↗

Elimination of depth degeneracy in optical frequency-domain imaging through polarization-based optical demodulation.

A novel optical frequency-domain imaging system is demonstrated that employs a passive optical demodulation circuit and a chirped digital acquisition clock derived from a voltage-controlled oscillator. The demodulation circuit allows the separation of signals from positive and negative depths to better than 50 dB, thereby eliminating depth degeneracy and doubling the imaging depth range. Our system design is compatible with dual-balanced and polarization-diverse detection, important techniques in the practical biomedical application of optical frequency-domain imaging.

Analog-Digital Conversion↗