A densitometric method for quantitative analysis of the left ventricle performance using i.v. digital subtraction angiography.

Abstract

In this paper we present a method we used to provide quantitative description of the systolic and diastolic temporal function of the left ventricle (LV). Additional parameters, such as peak filling and ejection rates, times to end systole and end diastole, and temporal changes in slow and fast filling are obtained. The volumes associated with these parameters are also calculated. Correlation between LV volume changes during the cardiac style and corresponding "density" variations was confirmed. Time-density curves were obtained from selected cardiac cycles in each study. We used the polynomial fitting technique to fit the time density curves and developed a computer algorithm for deriving the relevant parameters. Data from a total of 18 patients with ischemic heart or valvular diseases, who underwent I.V. ventriculography was analysed using our method. Some of these patients were forwarded for repeated digital subtraction angiography (DSA) examination before and after intervention therapy to evaluate the effectiveness of treatment. In comparison to the geometric method for the analysis of LV performance, our method is generally faster and simpler to employ. The method was effective in detecting variations in the peak ejection and filling rates in our group of patients before and after interventional therapy.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

A A Mustafa, J H Peregrin, M Simo, M S Adili, S A Saleh. A densitometric method for quantitative analysis of the left ventricle performance using i.v. digital subtraction angiography.. https://doi.org/10.1016/0895-6111(91)90136-j

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

A repeated measures concordance correlation coefficient.

The concordance correlation coefficient is commonly used to assess agreement between two raters or two methods of measuring a response when the data are measured on a continuous scale. However, the situation may arise in which repeated measurements are taken for each rater or method, e.g. longitudinal studies in clinical trials or bioassay data with subsamples. This paper proposes a coefficient for measuring agreement between two raters or two methods of measuring a response in the presence of repeated measurements. We illustrate the methodology with examples comparing (1) 1-hr versus 2-hr blood draws for measuring cortisol in an asthma clinical trial and (2) two measurements of percentage body fat, from skinfold calipers and dual energy X-ray absorptiometry.

Absorptiometry, Photon↗

Crystallization and preliminary X-ray analysis of a domain in the Runx2 transcription factor that interacts with the 1alpha,25 dihydroxy vitamin D3 receptor.

The Runx2 transcription factor is a key regulator of osteoblast differentiation. In response to 1alpha,25 dihydroxy vitamin D3, Runx2 may interact with the 1alpha,25 dihydroxy vitamin D3 receptor (VDR) in the promoter of target genes, producing a synergic activation of their transcription. Previous studies have suggested that the motifs responsible for the VDR-Runx2 interaction are contained within the 230-361 domain of Runx2. In this work, we confirmed by GST-pull down that Runx2(I(209-361)) is sufficient to interact with the VDR. To obtain structural information, GST-Runx2(I(209-361)) protein was overexpressed in Escherichia coli, purified and crystallized using the hanging-drop vapor-diffusion method and polyethyleneglycol as a precipitant. The crystals were found to diffract to a maximum resolution of 2.7 A and a complete data set to a 3.3 A resolution was collected and analyzed. The crystals belong to the tetragonal system, with a space group P4 and unit-cell parameters of a = b = 90.8, and c = 57.2 A. The presence of a monomer of the recombinant GST-Runx2(I(209-361)) in the asymmetric unit gives a V(M) of 2.7 A(3) Da(-1) and a solvent content of 54.8%.

Absorptiometry, Photon↗

Quantifying the treatment effect explained by markers in the presence of measurement error.

Surrogate markers or intermediate markers are important in identifying subjects with high risk of a serious disease or for monitoring disease progression of a subject on treatment. Quantifying the proportion of treatment effect (PTE) explained by markers has been studied extensively. Due to reasons such as biological variation, limited machine precision, etc. markers are generally measured with error. The estimated PTE ignoring the measurement error could be biased, which may lead to incorrect conclusions. In this article, we adjust for the measurement error using regression calibration to construct a less biased estimator of excess relative odds, a quantity to measure the treatment effect explained by markers. The method is applied to data from a clinical study in osteoporosis.

Absorptiometry, Photon↗