[Aging changes in ocular tissues and their influences on accommodative functions].

Abstract

It is well known that the amplitude of accommodation deteriorates with aging. However, it is not clear what kinds of morphological changes of age-dependent deterioration of amplitude of accommodation accompany in the crystalline lens and the ciliary muscle, which are the most important involved tissues in the accommodation mechanism. In the present study morphological changes of these tissues were investigated in relation to the deterioration of the accommodative amplitude. Age-dependent deterioration of the subjective amplitude of accommodation obtained by an accommodometer (VDT Accommodometer NP-200, Toyo-Medical, Nagoya) and the objective amplitude by an autorefractometer with a built-in infrared optometer (NIDEK AA 2000 Accommodometer, NIDEK, Gamagori, Japan) were compared. The objective amplitude was 2-3 dptr less than the subjective amplitude for all ages, but change of both curves with aging were parallel. The crystalline lens measured by an ultrasonic A-scan instrument, Alpha 20/20 (Storz, U.S.A.), showed continuous increase in thickness with aging and by accommodative contraction. The crystalline lens in the fifties was as same in thickness as the accommodatively contracted lens in the twenties but the increasing ratio of lens thickness in accommodative contraction decreased with aging and it reached a minimum in the sixties. Scanning electron microscopy (JSM F-15, JOEL Co, Tokyo) revealed three types of characteristic substructures on the cell surface of the crystalline lens fiber, ie, interlocking protrusion, ball-and-socket junction and microplica or the tongue-and-groove junction. In the lenticular nucleus the microplica was prominent on the cell surface throughout all ages but the ball-and-socket junction was sparse in number. On the other hand, the ball-and-socket junction was well developed on the cell surface in the superficial cortex of the lens. The microplica on the cell surface in the superficial cortex was recognizable but indistinct. The microplica and ball-and-socket junction seemed to shift relative to each other in the deeper cortex of the lens. The interlocking protrusion was recognized throughout the whole lens, but was prominent in the lenticular nucleus. The crystalline lens fibers of advanced age were irregural in shape and the spherical substructure, large and small in size, and frequently formed suggesting the cataractous change. Delicate shift of the ciliary processes after conjunctival application of 4% pilocarpine was confirmed by an angioendoscope (Angio Fiber Imaging System FCA-8000. Fukuda Electronics K.K., Tokyo) which was inserted into the vitreous space of cynomorgus monkey eyes.(ABSTRACT TRUNCATED AT 400 WORDS)

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

S Nishida. 1990. [Aging changes in ocular tissues and their influences on accommodative functions].. https://pubmed.ncbi.nlm.nih.gov/2114735/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Conceptual model of human blur perception.

An empirically based, conceptual model of human blur perception is presented. It incorporates the concepts of blur detection and blur discrimination in depth, and across the central and peripheral retina, in two- and three-dimensional visual space. Key aspects of the model are its dynamic nature, predictability regarding the blur-based depth-ordering of objects, patterns of retinal defocus with far and near viewing, and interactions related to retinal defocus between the central and peripheral retina. Furthermore, a two-dimensional schematic representation of the blur-free region during near viewing is depicted in dioptric space. This model has implications with respect to accommodative control, depth perception, and refractive error development and progression.

Accommodation, Ocular↗

The effect of human in vivo accommodation on crystalline lens stability.

AIM: To determine the effect of human in vivo accommodation on the stability of the crystalline lens. METHODS: Using a dual Purkinje image (DPI) eyetracker, the phase-time difference and amplitudes of Purkinje images I (P(I)) and IV (P(1V)) were measured in 37 normal emmetropic subjects (34 women and 3 men; mean age 19.8, range 18-22 years) when they changed focus from 70 to 15 cm and simultaneously rotated their heads horizontally from side to side or made horizontal saccades between two targets 6.8 degrees apart. RESULTS: When the subjects changed focus from 70 to 15 cm and rotated their heads or made eye saccades, the phase-time difference between P(I) and P(IV) decreased. During saccades, the amplitude of both P(I) and P(IV) overshoots significantly increased with focus at 15 cm; however, their ratio (P(IV) overshoot amplitude/P(I) overshoot amplitude) significantly declined. CONCLUSIONS: The lens is stable during accommodation. The implications of these findings on the mechanism of accommodation are discussed.

Accommodation, Ocular↗

Synchrony dual-optic accommodating intraocular lens. Part 2: pilot clinical evaluation.

PURPOSE: To evaluate the clinical outcomes of an accommodating dual-optic intraocular lens (IOL). SETTING: Private practice and university centers. METHODS: A prospective noncomparative case series with retrospective control comprised 21 patients (26 eyes) scheduled for small-incision extracapsular cataract extraction by phacoemulsification with implantation of the Synchrony dual-optic accommodating IOL (Visiogen) (accommodating IOL group) and 10 patients who had small-incision extracapsular phacoemulsification with implantation of a monofocal, single-optic IOL at least 6 months previously (control group). Patients were examined 1, 3, 6, and 12 months after surgery. Defocus curves in the accommodating IOL group were compared with those in the control group. The main outcome measures were postoperative distance uncorrected and best corrected visual acuity; near uncorrected, distance corrected, and near corrected visual acuity; and accommodative range based on defocus curves. RESULTS: Twenty-four eyes were available at the 6-month follow-up visit. All eyes had best corrected distance visual acuity of 20/40 or better, and 19 eyes (79%) had an uncorrected distance visual acuity of 20/40 or better. Uncorrected near visual acuity was 20/40 or better in all eyes. With distance correction, 23 eyes (96%) had an acuity of 20/40 or better at near. Defocus curve analysis suggested a mean accommodative range of 3.22 diopters (D) +/- 0.88 (SD) (range 1.00 to 5.00 D) in the accommodating IOL group and 1.65 +/- 0.58 D in the control group (range 1.00 to 2.50 D) (P<.05). CONCLUSION: The Synchrony dual-optic IOL shows promise as an option to provide accommodative function in pseudophakic patients.

Accommodation, Ocular↗