Tissue response to percutaneous implants in rabbits.
Abstract
This study reports on certain aspects of wound-healing around percutaneous implants. Plasma-sprayed and dense hydroxylapatite, titanium, and carbon test implants were inserted into the tibia and the cranium of 12 rabbits. Four and 8 months after insertion, the animals were sacrificed and the implants with their surrounding tissues were processed histologically. Light- and transmission electron microscopic investigations were performed. It is found that direct and indirect bone-anchoring favors the longevity of percutaneous implants. No differences in tissue reaction between the various implant materials were observed.
Explore related subjects
Keep this discovery
Explore connections, maps & timelines
J A Jansen, J P van der Waerden, H B van der Lubbe, K de Groot. 1990. Tissue response to percutaneous implants in rabbits.. https://doi.org/10.1002/jbm.820240303