PubMed Health⌕ Search

PubMed · 2707274

An accurate exercise lead system for bicycle ergometer tests.

Abstract

In order to minimize muscle noise in the exercise electrocardiogram, Mason and Likar proposed a new lead system where the limb electrodes are instead placed on the trunk. The Mason-Likar system is widely used for both the resting ECG before exercise and recordings during exercise. Several studies have, however, reported great differences between this lead system and the standard lead system. This study shows greater R wave amplitudes in leads II, aVF and III, smaller R wave amplitudes in leads aVL and I and thus a vertical shift of the frontal plane QRS axis for the Mason-Likar system compared with the standard system. For many years another lead system for exercise tests with the bicycle ergometer has been used in our laboratory. The limb electrodes are placed at the proximal part of the arms and the left iliac crest. This lead system yields ECG signals with a low level of muscle noise. The differences between this lead system and the standard ECG are much less pronounced than the differences between the Mason-Likar ECG and standard ECG. We propose our lead system for exercise tests with the bicycle ergometer.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

L Edenbrandt, O Pahlm, L Sörnmo. 1989. An accurate exercise lead system for bicycle ergometer tests.. https://doi.org/10.1093/oxfordjournals.eurheartj.a059475

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Three-dimensional reconstruction of the ankle by means of ultrathin slice plastination.

Computerized reconstruction of anatomical structures is becoming very useful for developing anatomical teaching modules and animations. Although databases exist consisting of serial sections derived from frozen cadaver material, plastination represents an alternate method for developing anatomical data useful for computerized reconstruction. Plastination is used as an excellent tool for studying different anatomical and clinical questions. The sheet plastination technique is unique because it offers the possibility to produce transparent slices series, which can easily be processed morphometrically. The purpose of this study was to describe a method for developing a computerized model of the human ankle using plastinated slices. This method could be applied to reconstruct any desired region of the human body.A human ankle was obtained, plastinated, sectioned, and subjected to 3D computerized reconstruction using WinSURF modeling system (SURFdriver Software). Qualitative observations revealed that the morphological features of the model were consistent with those displayed by typical cadaveric specimens. Morphometric analysis indicated that the model did not significantly differ from a sample of cadaveric specimens. These data support the use of plastinates for generating tissues sections useful for 3D computerized modeling.

Ankle↗

Intraepidermal nerve fiber density as a marker of early diabetic neuropathy.

The purpose of the study was to reliably identify an early stage of diabetic polyneuropathy (DPN) by measuring injury to epidermal nerve fibers. We compared intraepidermal nerve fiber density (IENFD) at the ankle and thigh of 29 diabetic subjects who had no clinical or electrophysiological evidence of small- or large-fiber neuropathy to that of 84 healthy controls. The mean ankle IENFD of diabetic subjects was 9.1+/-5.0 mm and that of controls, 13.0+/-4.8 mm (P<0.001). The thigh IENFD did not differ significantly. The IENFD ratio (thigh IENFD divided by ankle IENFD) was 2.39+/-1.30 in diabetic subjects and 1.77+/-0.58 in controls (P<0.001), indicating a length-dependent reduction of IENFD in diabetics. Ankle IENFD remained significantly lower and the IENFD ratio higher in diabetic subjects after adjusting for age. Two subjects had parasympathetic dysfunction, two had retinopathy, and two early nephropathy. Age, height, weight, duration of diabetes, and average HbA1c did not influence IENFD among diabetic subjects. We used receiver operating characteristic (ROC) curves to describe and compare the utility of various threshold values of ankle IENFD and IENFD ratio for the diagnosis of early DPN. The sensitivity and specificity of diagnosing DPN using ankle IENFD of less than 10 mm were 72.4% and 76.2%, respectively. Thus, asymptomatic diabetics have a measurable, length-dependent reduction of distal epidermal nerves. Analogous to microalbuminuria in diabetic nephropathy, reliable identification and quantitation of nascent diabetic neuropathy may have potential therapeutic implications.

Ankle↗

[Diagnostic imaging of nerve compression syndrome].

Compression-induced neuropathy of peripheral nerves can cause severe pain of the foot and ankle. Early diagnosis is important to institute prompt treatment and to minimize potential injury. Although clinical examination combined with electrophysiological studies remain the cornerstone of the diagnostic work-up, in certain cases, imaging may provide key information with regard to the exact anatomic location of the lesion or aid in narrowing the differential diagnosis. In other patients with peripheral neuropathies of the foot and ankle, imaging may establish the etiology of the condition and provide information crucial for management and/or surgical planning. MR imaging and ultrasound provide direct visualization of the nerve and surrounding abnormalities. Bony abnormalities contributing to nerve compression are best assessed by radiographs and CT. Knowledge of the anatomy, the etiology, typical clinical findings, and imaging features of peripheral neuropathies affecting the peripheral nerves of the foot and ankle will allow for a more confident diagnosis.

Ankle↗