PubMed HealthSearch

PubMed · 290807

A method to measure operating variables in electrosurgery.

Abstract

Variables affecting tissue response to electrosurgical wounding have been identified and discussed. An electronic measuring device was designed and built to record actual power generated at the active electrode during surgical use of an electrosurgery instrument. In addition, this electronic device measures the amount of time the active electrode is in contact with tissue. Coupled with an electrosurgery unit producing a documented waveform and an electrosurgery electrode having a controlled-depth gauge, variables affecting tissue response to electrosurgery wounding may be measured.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

K L Kalkwarf, R F Krejci, A R Edison. 1979. A method to measure operating variables in electrosurgery.. https://doi.org/10.1016/0022-3913(79)90255-5

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

[Romantic origins of electrophysiology].

Research on static electricity and its effects on the human body date back to the invention of the electrizing or Wimshurst machine and the Leyden jar of 1743 and 1746. Such experiments often served as social pastimes, but they yielded many publications on medical aspects of static electricity. Attempts to explain the 'life force' of the vitalists and the old concept of the active principle of the nervous system, the 'spiritus animales', as electrical phenomena were unsuccessful because of the skeptic comments of leading experimental scientists such as Albrecht von Haller. When Mesmer reinvented 'animal magnetism' in 1776 as a fashionable term for treatment by suggestion, he appropriated theoretical, technical and social methods from the established ways of the experiments on static electricity. Therefore, the scientific character of Luigi Galvani's investigations was already compromised by his term 'animal electricity' when he published his famous 'Commentarius' in 1781. Volta in Pavia turned against Galvani, proving that galvanic currents are produced by metals alone, and rejecting 'animal electricity'. Volta's doctrine prevailed over Galvani's school after Volta's breakthrough with his pile, or battery, until Galvani's ideas were rehabilitated by Nobili, who in 1828 measured the 'frog current' with his galvanometer. This led to a flurry of bizarre experiments on rows of half-dismembered animals and severed parts of human cadavers. Johannes Müller in Berlin, who, with his students, established new principles of biology and neurology, asked Du Bois-Reymond to study these experiments. Du Bois-Reymond found that measurements of muscle currents in intact animals were more useful, and he compared them with his own observations on electric fishes.(ABSTRACT TRUNCATED AT 250 WORDS)

Electricity

Effect of mains interference on time coherent averaging.

The paper deals with the influence of mains interference on time coherent averaging using an internal trigger. The general distribution of the time jitter is derived and applied to a simplified signal. The authors prove that no amount of averaging can do away with this type of interference. Finally, the deformation this type of jitter has on a step signal is computed.

Electricity

The influence of spatial polarization distribution on spot poled PVDF membrane hydrophone performance.

The influence of spatial polarization distribution on spot poled PVDF membrane hydrophone performance was calculated and then experimentally verified using a one-dimensional model based on acoustic wave propagation through a layered medium. It is shown that the sensitivity of the hydrophone is markedly dependent on the spatial polarization distribution. It is also shown that there can be a significant difference between the voltage sensitivities measured in the same hydrophone probe depending on which electrode is actually facing the acoustic source. The measurements carried out in the frequency range 1-20 MHz indicate that this difference, while negligible below 2 MHz, may exceed 1.6 dB at higher frequencies. The model developed can also be used to determine the "effective" piezoelectric constant d33 of the PVDF material as a continuous function of frequency. Moreover, the model predicts the existence of a negative slope in the frequency response of the spot poled membrane hydrophone. The experimental confirmation of this prediction underscores the importance of using swept frequency methods during calibration measurements.

Electricity