Defining a standard intubating position using "angle finder".

Abstract

Study of patients who exhibit only limited morphological abnormality yet present difficulty with direct laryngoscopy is facilitated by a standard intubating position. The "Angle Finder" instrument allows implementation of a simple reproducible geometric standard which is applied easily in formal research work and in clinical practice and teaching. The proposed standard relates to the curved (Macintosh) laryngoscope blade and a supine patient. The lower neck flexion is 35 degrees and extension of the plane of the face 15 degrees, each angle measured relative to horizontal. Initially, the standard was derived from a review of the literature, then validated in a study of the intubating practices of 10 senior anaesthetists. A more detailed study of 10 normal volunteers confirmed reproducibility and, for nine patients with a history of difficult direct laryngoscopy, the standard was shown to be appropriate.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

W A Horton, L Fahy, P Charters. 1989. Defining a standard intubating position using "angle finder".. https://doi.org/10.1093/bja%2F62.1.6

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

MRI segmentation: methods and applications.

The current literature on MRI segmentation methods is reviewed. Particular emphasis is placed on the relative merits of single image versus multispectral segmentation, and supervised versus unsupervised segmentation methods. Image pre-processing and registration are discussed, as well as methods of validation. The application of MRI segmentation for tumor volume measurements during the course of therapy is presented here as an example, illustrating problems associated with inter- and intra-observer variations inherent to supervised methods.

Head

Parametrization of head-scatter factors for rectangular photon fields using an equivalent square formalism.

Head-scatter factors of symmetric square and rectangular fields (field center on the central beam axis) defined by the upper (Y) and lower (X) jaws for 6 and 15 MV photon beams from 2300CD and 600C accelerators (Varian Associates, Inc., Palo Alto, CA) were measured, as well as those for fields shaped by the Y jaws and the multileaf collimator (MLC) of the 2300CD. For rectangular fields, the head-scatter factor for the field (x = a and y = b) was different from that for the field (y = a and x = b). This difference was 2% -3% for fields defined by conventional collimators when [formula, see text] was large, and became 4%-5% when the MLC and YT jaws were used to shape the fields with the X jaws retracted. In order to calculate values for head-scatter factors of rectangular fields accurately using an equivalent square formalism, the side of the equivalent square should be obtained with different weights for lower and upper jaws, as proposed by Vadash and Bjärngard [Med. Phys. 20, 733-734 (1993)]. Our measurements demonstrate that the relative weight (G) of upper and lower jaws is strongly dependent on their distances from the x-ray source, while the beam energy has little effect on the value of G. We further show that G can be calculated simply from these distances. An analytical representation for head-scatter factors of square and rectangular fields is also developed in this paper. The quality of this representation was judged by the root-mean-square (rms) deviation from measured head-scatter factors, which ranged from 0.11%-0.27%.

Head