PubMed HealthSearch

PubMed · 3209596

A television/computer three-dimensional surface shape measurement system.

Abstract

An optical scanner is described which has been designed primarily for the measurement of human back shape. A projector and television camera were mounted together in a box which could rotate about a horizontal axis. The projector shone a horizontal plane of light, which was viewed at an angle from below by the television camera, linked directly to a minicomputer. The shape of the line of light formed by the plane as it fell on an object, together with a knowledge of the geometry of the system, enabled three-dimensional coordinates of points on the line to be calculated. A record of a surface shape was built up by scanning the object in about 2 s. Calibration of the system was achieved by scanning an object of known dimensions. Sets of algorithms are described which derive geometric parameters from the calibration scan and which sort surface shape coordinates, outline them and detect special markers from the surface shape scan. The accuracy of measurement exceeded the design aim of +/- 3 mm in each axis within a volume of 400 mm x 500 mm x 300 mm.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

A R Turner-Smith. 1988. A television/computer three-dimensional surface shape measurement system.. https://doi.org/10.1016/0021-9290(88)90244-8

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Clinical cardiomyoplasty: preoperative factors associated with outcome.

Dynamic cardiomyoplasty has been used clinically to augment the ventricular function of a failing heart. Fifteen clinical dynamic cardiomyoplasties have been performed at Allegheny General Hospital since 1985. Left ventricular ejection fraction improved in long-term survivors from a preoperative value of 0.23 +/- 0.02 to 0.32 +/- 0.05 with postoperative cardiomyostimulation (p < 0.05). There was an average reduction of 2 +/- 0.3 New York Heart Association classes (3.6 +/- 0.2 before operation versus 1.6 +/- 0.4 after operation; p < 0.001). Postoperative mortality was 27% (4/15), and early mortality (within 6 months after operation) was 20% (3/15). Significant preoperative differences between survivors and nonsurvivors were found in right ventricular ejection fraction (0.53 +/- 0.03 versus 0.30 +/- 0.07; p < 0.05), pulmonary artery mean pressure (19 +/- 2 versus 34 +/- 6 mm Hg; p < 0.05), pulmonary artery diastolic pressure (12 +/- 1 versus 25 +/- 5 mm Hg; p < 0.05), and pulmonary vascular resistance (1.4 +/- 2 versus 2.5 +/- 0.7 Wood units; p < 0.05). Dynamic cardiomyoplasty can be done with low operative mortality in patients with isolated left ventricular failure, but mortality is high in those with biventricular failure or pulmonary hypertension. Improvement in functional class and ventricular function can be expected in long-term survivors. Application of these findings to patient selection will improve the risk/benefit ratio for dynamic cardiomyoplasty.

Back

"X Lite": a protective shield for skin grafts on the back.

"X Lite", a thermoplastic material was used in eight patients as a splint for protecting split skin grafts on the back. After an average stay of 4.3 days patients were discharged with no incidence of graft failure. The patients involved felt comfortable whilst remaining supine. We believe time saved by adequate protection leading to successful grafts makes this method economically useful.

Back

Back closure with a latissimus dorsi myocutaneous flap.

A method of back closure with the use of latissimus dorsi myocutaneous flap in cases of myelomeningocele is reported. A three-layer cover consisting of the skin, subcutaneous fat, and the muscle with proper innervation and blood supply of the flap permits successful closure of large defects. Well-vascularized coverage prevents common complications such as partial necrosis of the flap or wound breakdown and consequent infection of the central nervous system. This report is based on 30 cases of newborns with large thoracolumbar myelomeningocele.

Back