Preventing ceramic failures when integrating fixed and removable prostheses.

Abstract

The successful integration of fixed and removable units requires diagnostic skill, careful planning, and adherence to detail in execution. Failures can be either in function or esthetics, may occur in either the fixed or removable segment, and can be catastrophic or insidious. Success demands that all the customary requirements for each independent unit, fixed or removable, be met and then the additional requirements for integration be ascertained and fulfilled. In such situations there are an exponentially greater number of possibilities for failure. When the dentist is alert to the potential for failure he may intercept and prevent it. Meticulous care pays long-term dividends in the lasting satisfaction of a patient who enjoys imporved masticatory performance, preservation of the existing tissues, and self-confidence borne from a smile that does not reveal differences between the natural and the simulation of nature. The integration of fixed and removable units is another manifestation of the skillful blending of science and art.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

J D Preston. 1979. Preventing ceramic failures when integrating fixed and removable prostheses.. https://pubmed.ncbi.nlm.nih.gov/365632/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Influence of P2O5 on crystallinity of apatite formed in vitro on surface of bioactive glasses.

Two sol-gel glasses with 80 mol % SiO2 were prepared in the system SiO2-CaO-P2O5; the first one had 3 mol% P2O5 in its composition, and the second one was P2O5 free. The in vitro behavior of glasses was studied by soaking them in simulated body fluid for 7 days at 37 degrees C. After the in vitro test, the study by Fourier transform infrared spectroscopy, scanning electron microscopy, energy dispersive spectroscopy, electron diffraction, and transmission electron microscopy showed an apatite-like layer had formed on the surface of both glasses. However, for identical soaking time, the apatite crystals formed on the surface of the glass containing P2O5 in the composition were larger. Therefore, the presence of P2O5 in the sol-gel glass composition promotes the crystal growth of the apatite.

Ceramics

Effect of heat treatment on microcrack healing behavior of a machinable dental ceramic.

The purpose of this study was to evaluate the effect of annealing in air on the crack healing behavior of a machinable dental ceramic (Vita Mark II). The glass transition temperature and the softening point were determined by dilatometry. Polished Vita Mark II blocks (n = 12) were indented with a Vickers indenter under a 9.8 N load. Optical micrographs were taken immediately after indentation, and the crack lengths were measured. The specimens were annealed at 900 degrees C for either 30 min, 1 h, or 2 h. One group was indented and heat treated at 400 degrees C for 2 h as control. The ratio of crack length after annealing to crack length before annealing treatment was calculated for each indentation. Scanning electron microscopy was performed before and after annealing at 900 degrees C for 1 h. Scanning electron microscopy revealed shortening and blunting of the cracks after annealing. Annealing in air at 900 degrees C for either 30 min, 1 or 2 h significantly reduced the mean crack length of an indented machinable dental ceramic compared to the control group. However, the mean biaxial flexural strength was not significantly affected by an annealing treatment.

Ceramics

Effect of luting composite shrinkage and thermal loads on the stress distribution in porcelain laminate veneers.

STATEMENT OF PROBLEM: Cyclic thermal fatigue has demonstrated a significant influence of the thicknesses of luting composite and ceramic in crack propensity of porcelain laminates. PURPOSE: This study was conducted to define potentially involved parameters for crack development in porcelain laminates bonded to teeth. Finite element modeling was used to evaluate the respective effects of luting composite shrinkage and significant thermal changes. MATERIAL AND METHODS: A buccolingual cross-section of a maxillary incisor was digitized and used as a template to generate a single 2-dimensional mesh, including all the different restorative designs. Luting composite shrinkage was simulated at a baseline temperature of 20 degrees C. The effect of thermal loads from 20 degrees C to 5 degrees C and from 20 degrees C to 50 degrees C was assessed with and without preexisting composite shrinkage. RESULTS: Shrinkage of the luting composite alone generated important compressive forces on the ceramic, either at the restoration surface or interface. Compression intensity was related to geometry and ratio of thicknesses between the ceramic and luting composite (CER/CPR). Lower ratios produced higher compression forces in the ceramic. When thermal loads were combined to the composite shrinking forces, the stress pattern was significantly changed only for the experimental conditions with the lowest CER/CPR ratio. Temperature increase reduced compressive stresses and exacerbated tensile stresses. Thermal loads were simulated alone (situation of an "ideal nonshrinking" luting composite) and generated mainly tensile stresses in the ceramic, which intensity was again modulated by the CER/CPR ratio and the local geometry of composite and ceramic. Because of ceramic brittleness, these tensile forces were more detrimental than the high compression created by composite shrinkage alone. The stress pattern was not influenced by the incisal length of the veneer but rather by the facial thickness of ceramic. The worst record made with a shrinking luting agent (500 microm of luting composite, lowest CER/CPR ratio, 5 degrees C) was much less harmful than the worst record made with a hypothetical "nonshrinking" luting material. CONCLUSIONS: The ratio of the thickness of cement and luting composite appears to have a relevant influence on the stress distribution in porcelain laminates. Restorations that are too thin, combined with poor internal fit, resulted in higher stresses at both the surface and interface of the restoration. Because of its precompressed state given by composite shrinkage, ceramics performed better with regard to temperature-induced tensile forces.

Ceramics