Microcomputer system for the analysis of muscle function.

Abstract

Though skeletal muscle function has recently been increasingly studied, a system for routine clinical examination in patients is not widely available. A microcomputer based system has been developed for the measurement and analysis of force-frequency characteristics, relaxation rate, fatiguability and endurance in the adductor pollicis muscle. The mobile system consists of a modified displacement transducer fitted with a linear-output Hall-effect sensor, a specially designed signal processing unit and a microcomputer for control of both the electrical stimulus and a suite of menu-driven, user-interactive programs. One hundred normal volunteers have been studied to produce a normal database for comparison with malnourished surgical patients. The system compares favourably with other systems in use for objective measurement of skeletal muscle function and introduces a refined technique for evaluating endurance.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

S J McLaughlin, S T Chan, D Ford, S J Neame, H A Dudley. 1987. Microcomputer system for the analysis of muscle function.. https://doi.org/10.1016/0141-5425(87)90101-4

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Optimal design of non-Newtonian, micro-scale viscous pumps for biomedical devices.

The present paper addresses the numerical optimization of geometrical parameters of non-Newtonian micro-scale viscous pumps for biomedical devices. The objective is to maximize the mass flow rate per unit of shaft power consumed by the rotor when an external pressure load is applied along the channel that houses the rotor. Two geometric parameters are considered in the optimization process: (i) the height of the channel that houses the rotor (H) and (ii), the eccentricity (epsilon) of the rotor. Three different micro-scale viscous pump configurations were tested: a straight-housed pump (I-shaped housing) and two curved housed pumps (L- and U-shaped housings). The stress-strain constitutive law is modeled by a power-law relation. The results show that the geometric optimization of micro-scale viscous pumps is critical since the mass flow rate propelled by the rotor is highly dependent on epsilon and H. Numerical simulations indicate that mass flow rate is maximized when epsilon approximately 0, namely when the rotor is placed at a distance of 0.05 radii from the lower wall. The results also show that micro-scale viscous pumps with curved housing provide higher mass flow rate per unit of shaft power consumed when compared with straight-housed pumps. The results are presented in terms optimized dimensions of all three configurations (i.e., H(opt) and epsilon(opt)) and for values of the power-law index varying between 0.5 (shear thinning fluids) and 1.5 (shear-thickening fluids).

Biomedical Engineering↗