PubMed HealthSearch

PubMed · 3993550

Hemodynamic adaptations to exercise.

Abstract

It is not currently known whether central hemodynamic or peripheral (vascular or metabolic) factors limit maximal oxygen uptake. By measuring the blood flow and oxygen uptake of exercising muscles when only a small fraction of the total muscle mass is engaged in exercise, it has been demonstrated that the skeletal muscle of man could accommodate a blood flow of at least 200 ml/100 g min, and consume 300 ml O2/100 g min at exhaustive exercise. Thus, in whole body exercise the limiting factor is the capacity of the heart to deliver oxygen, not the muscle. It has also been observed that at high perfusion of the muscle the arteriovenous O2 difference is small (14 to 15 vol %), and that the low extraction of oxygen is related to the mean transit time (MTT) of red blood cells passing through the capillaries. It has been concluded that the primary importance of enlargement of the capillary bed with endurance training is not to accommodate flow but to maintain or elongate MTT. It has also been concluded that, in whole body exercise, the capacity of the muscles to receive a flow exceeds by a factor of 2 to 3 the capacity of the heart to supply the flow. Thus, vasoconstrictor tone must also be present in the arteries that "feed" exercising muscles.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

B Saltin. 1985-04-26. Hemodynamic adaptations to exercise.. https://doi.org/10.1016/0002-9149(85)91054-9

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Caval contribution to flow in the branch pulmonary arteries of Fontan patients with a novel application of magnetic resonance presaturation pulse.

BACKGROUND: A complete understanding of fluid mechanics in Fontan physiology includes knowledge of the caval contributions to right (RPA) and left (LPA) pulmonary arterial blood flow, total systemic venous return, and relative blood flow to each lung. METHODS AND RESULTS: Ten Fontan patients underwent cine MRI. Three cine scans of the pulmonary arteries were performed: (1) no presaturation pulse, (2) a presaturation pulse labeling inferior vena cava (IVC) blood (signal void), and (3) a presaturation pulse labeling superior vena cava (SVC) blood. The relative signal decrease is proportional to the amount of blood originating from the labeled vena cava. This method was validated in a phantom. Whereas 60+/-6% of SVC blood flowed into the RPA, 67+/-12% of IVC blood flowed toward the LPA. Of the blood in the LPA and RPA, 48+/-14% and 31+/-17%, respectively, came from the IVC. IVC blood contributed 40+/-16% to total systemic venous return. The distributions of blood to each lung were nearly equal (RPA/LPA blood=0.94+/-11). CONCLUSIONS: In Fontan patients with total cavopulmonary connection, SVC blood is directed toward the RPA and IVC blood is directed toward the LPA. Although the right lung volume is larger than the left, an equal amount of blood flow went to both lungs. LPA blood is composed of equal amounts of IVC and SVC blood because IVC contribution to total systemic venous return is smaller than that of the SVC. This technique and these findings can help to evaluate design changes of the systemic venous pathway to improve Fontan hemodynamics.

Blood Flow Velocity

Using flow relaxography to elucidate flow relaxivity.

We have investigated the theoretical and experimental linear dependence of the reciprocal of the apparent longitudinal relaxation time [(T*1)-1] of the NMR signal from spins in a flowing fluid on the volume flow rate, Fv, the so-called inflow effect. We refer to the coefficient of this dependence as the longitudinal flow relaxivity, r1F. A very simple model predicts that, under a range of conditions pertinent to modern flow studies and perfusion imaging experiments, r1F is controlled by the volume of the fluid in which the magnetization is perturbed by pulsed RF inversion or saturation, not the detection volume, and that it can be approximated as the reciprocal of half of the inversion volume. Phantom sample experiments, using a new, quantitative approach that we call flow relaxography, confirm the general predictions of this simple model. There are two intriguing implications of these findings for general NMR flow studies as well as for medical applications. It should be possible to vary the value of r1F by simply (noninvasively) adjusting the inversion slice thickness, and thus measure the value of (blood 1H2O, for example) Fv in a vessel without changing Fv, from the resultant varying T*1 values. Also, it should be possible to extrapolate to the intrinsic T1 value of the fluid signal (as if it were stationary), without altering or stopping the flow. Again, these are quite successful in phantom sample studies. Imaging versions of the flow relaxographic experiments are also possible. The twin goals of flow studies in medical MRI are the quantitative discrimination of the signals from flowing and nonflowing spins, and the accurate measurement of the flow rate of the former.

Blood Flow Velocity

Amplitude-coded color doppler: clinical applications.

Amplitude-coded color Doppler sonography (ACD) has become an useful adjunct to gray-scale US and conventional color Doppler sonography (CD) for the assessment of vascular diseases and pathologic conditions that might affect or alter tissue vascularization or perfusion. Basically, all US units that generate conventional color Doppler information through autocorrelation technique are capable of displaying ACD. This technique is also referred to as power Doppler, amplitude-mode color Doppler US, color Doppler energy (CDE), or US angiography. Amplitude-coded color Doppler sonography has already emerged as a valuable adjunct to conventional CD, particularly for evaluating flow in parts of the body where CD signal is weak because of slow flow, small blood vessels, or both.

Blood Flow Velocity