PubMed HealthSearch

PubMed · 4000905

Shape sensing for computer aided below-knee prosthetic socket design.

Abstract

Shape sensing is useful in the computer aided prosthetic fitting process for two purposes. 1. To input characteristic prosthetic shapes that have been developed over the years through the experience of prosthetists. 2. To provide an accurate and rapid measurement of the anatomical shape of the stump. This paper describes two instruments which have been built to meet these objectives.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

G R Fernie, G Griggs, S Bartlett, K Lunau. 1985. Shape sensing for computer aided below-knee prosthetic socket design.. https://doi.org/10.3109/03093648509164818

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Interface mechanics in external prosthetics: review of interface stress measurement techniques.

Instrumentation to measure accurately the stresses at the interface of a residual limb and prosthetic socket has a strong potential for use in prosthetic treatment. As a tool in the clinical setting, the device would allow a clinician to identify sites of excessive loading, information which could then be combined with clinical assessment of skin quality to determine regions of potential skin breakdown. Stress distributions for different prosthetic designs could be compared, facilitating a clinician's judgement to determine the optimal design for a patient. The instrumentation would have additional use in research as an evaluation tool for computer-based finite-element (FE) models. Stump-socket FE models predict stress distributions for proposed socket designs, thus offering advantages over interface stress measurement because evaluation can be conducted before a prosthesis is fabricated or put on an amputee patient. However, FE models must first be proven valid against experimental measurements before they can be considered accurate predictors of interface stresses. Current interface stress measurement techniques are described, with a concentration on a physical explanation of the advantages and limitations with each technique. New emerging technologies are discussed which are instruments that have been described but for which no data collected on amputees have been reported in the literature. The important new features of those technologies are also discussed.

Amputation Stumps

Closure of an open high below-knee guillotine amputation wound using a skin-stretching device.

A skin-stretching device (SSD) which is designed to harness the viscoelastic properties of the skin using incremental traction is described. It has proved to be of value in securing closure, within 72 h, of an open high below-knee guillotine stump wound which did not heal during a period of 2 months after amputation. The skin-stretching device provided healthy, durable and sensate skin for stump coverage. Hospitalization time was shortened and an early post-surgical prosthetic fitting and ambulation was achieved.

Amputation Stumps

Phantom limb pain: are cutaneous nociceptors and spinothalamic neurons involved in the signaling and maintenance of spontaneous and touch-evoked pain? A case report.

A patient suffered multiple fractures of the right leg and a left brain-stem infarction involving the anterolateral fasciculus of the central nociceptive system following multiple trauma. Later, the right leg was amputated, resulting in spontaneous and touch-evoked phantom pain and mechanical stump allodynia. However, quantitative sensory testing revealed considerable impairment of sensations normally mediated by cutaneous nociceptors and central spinothalamic systems on the right body side, including the stump but nearly intact touch and vibration senses. Quantitative assessment of peripheral nociceptive C-fiber function (axon reflex vasodilatation and flare) showed no abnormalities on both sides. Sympathetic blocks did not change spontaneous and evoked pain. Epidural and spinal anesthesia abolished evoked pain but had no effect on spontaneous phantom pain. Extirpation of a neuroma of the sciatic nerve did not alter spontaneous and evoked pain. TENS resulted in an increase in pain. We concluded the following. (i) Painful somatosensory memories that are responsible for phantom limb pain are located in the brain, most probably in the thalamus or cortex. (ii) Touch-evoked phantom pain and stump allodynia are not mediated by cutaneous nociceptive C and A delta fibers and spinal nociceptive pathways (spinothalamic tract). Activity in the lemniscal system (low-threshold mechanoreceptive A beta afferents, dorsal columns and medial lemnicus system) may be transferred to central pain signaling neurons in the thalamus or cortex resulting in touch-evoked pain sensations. (iii) Ongoing activity in cutaneous nociceptive C fibers and spinal nociceptive systems is not necessary to maintain central processes that account for spontaneous and touch-evoked pain sensations. Activity in nociceptors of deep somatic tissues might be more important.

Amputation Stumps