PubMed HealthSearch

PubMed · 4496727

[Cardiac risks in bronchoscopy].

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

W Schilling, K Wetzer, D Wenzel. 1974. [Cardiac risks in bronchoscopy].. https://pubmed.ncbi.nlm.nih.gov/4496727/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

[ARDS caused by military zinc fumes exposure].

A previously healthy 19-year-old male was exposed to concentrated hexite smoke (ZnCl2) for several minutes during military training. The initial symptoms (vomiting, cough, dyspnea) disappeared after a few hours. After 48 hours the patient developed acute respiratory distress syndrome requiring tracheal intubation and mechanical ventilation for 8 days. He left hospital 10 days after extubation. Spirometry at this time revealed a restrictive defect (vital capacity 50% predicted). Four months after the accident the patient had returned to work without symptoms of respiratory insufficiency. Lung function tests had normalized with the exception of a slight reduction in carbon monoxide diffusion. This case illustrates the typical course of inhalative intoxication with hexite. It underlines the importance of prolonged clinical surveillance in view of the latency between the initial symptoms of hexite intoxication and possible later development of ARDS.

Blood Gas Analysis

Intra-arterial blood gas monitoring system: more accurate values can be obtained.

OBJECTIVE: To compare values measured by a continuous intra-arterial blood gas monitoring system with those measured by conventional blood gas analyzer for the assessment of the clinical performance of a new device for measurement of PaO2, PaCO2, and arterial pH. METHODS: Forty-six patients undergoing cardiopulmonary bypass were enrolled in this study. All patients had a continuous intra-arterial sensor (PB 3300) placed into the radial artery through a 20-gauge catheter. A total of 319 arterial blood gas and pH values were obtained for comparison with a conventional blood gas analyzer. The measurements were performed every 12 hrs after the initial in vitro calibration of the sensor for each patient. RESULTS: Measurements were made over a range of 12 to 192 hrs. The overall bias and precision determined by the two methods were 4.5 and 17.1 mmHg for PaO2; 4.5 and 6.2 mmHg for PaCO2; and 0.009 and 0.035 for pH, respectively. For the range of PO2 less than 150 mmHg, the bias and precision improved to 4.2 and 9.5 mmHg. The sensor-derived PCO2 value, PCO2 (IABG), increased significantly more than the conventional blood gas analysis value, PCO2(ABG), even within 72 hrs (2.8 and 4.1 mmHg). The relationship between the two measurements can be described as: PCO2(IABG)/PCO2(ABG) = 1 + 0.0026.t where t is the time period of use (in hours). By correcting the PCO2(IABG) value using this formula, the overall bias and precision of the values measured by two methods decreases to -0.4 and 3.6 mmHg. CONCLUSIONS: The PO2 and pH values derived from an intra-arterial blood gas monitoring system agreed well with the values measured by a conventional blood gas analyzer. However, the PCO2 value must be corrected due to an increase of drift, especially with extended use for more than 72 hours.

Blood Gas Analysis