PubMed Health⌕ Search

PubMed · 455132

The nasal step in normal and glaucomatous visual fields.

Abstract

We used an original method of kinetic and static analysis to examine the nasal visual field. When the nasal step is less than 4 degrees wide and its depth is less than 0.5 log units it may be merely a physiological sign of the anatomic and functional asymmetry of the retina. Sometimes it is an artifact. The nasal step can also be a glaucomatous defect. In this case it is often an early sign and it is wider than 4 degrees and its depth is greater than 0.5 log units. Because of its typical shape and invariable location it is easy to discover by kinetic perimetry and easy to check by static perimetry. If it is an early glaucomatous defect, it can be reversed. In practice the nasal step is an early and characteristic glaucomatous field defect like the isolated scotomas in the Bjerrum area, and it is easily detected and can be used as a sensitive marker in the follow up of glaucomatous damage.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

M Zingirian, G Calabria, E Gandolfo. 1979. The nasal step in normal and glaucomatous visual fields.. https://pubmed.ncbi.nlm.nih.gov/455132/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Do scleral flap dimensions influence reliability of intraocular pressure control in experimental trabeculectomy?

AIM: To compare the effect on intraocular pressure (IOP) of large vs small scleral flap size during trabeculectomy using adjustable sutures. METHODS: Trabeculectomy operations were performed on nine donor human eyes connected to a constant flow infusion with real-time IOP monitoring. Large scleral flaps (4 x 4 mm, 16 mm(2), n=12) or small scleral flaps (3 x 2 mm, 6 mm(2), n=9) were constructed over 0.76 mm(2) sclerostomies. For each procedure, equilibrium IOP was measured following tight closure with two four-throw adjustable 10-0 nylon sutures. RESULTS: Five scleral flaps were thin or poorly constructed; four of these were in the initial seven procedures, implying learning effect. These had a mean absolute IOP of 7.6 mmHg (range 2.7-12.4 mmHg) and mean relative IOP of 28.3% of baseline (range 10-45.8%) after closure. In the remaining 16 good quality procedures, mean IOP was 1.3 mmHg (range 0-3.4 mmHg) after sclerostomy, confirming minimal outflow resistance before closure. Following flap closure mean IOP was 20 mmHg (SD 4.4, range 15.5-29.3 mmHg) for large (n=8), and 18.7 mmHg (SD 3.6, 15.9-25.8 mmHg) for small (n=8) flaps (unpaired t-test, P=0.26). Mean IOP (% baseline) was 71.6% (SD 8.4, range 60.6-86.6%) and 66% (SD=12.7, 46.8-86.6%) for large and small flap groups, respectively (unpaired t-test, P=0.2). CONCLUSIONS: Well-constructed scleral flaps of both sizes were able to support an average IOP at least two-thirds of baseline, and both had similar absolute IOP levels. Errors in flap construction resulted in loss of IOP control. Smaller flap size does not appear to compromise control of early postoperative IOP using adjustable sutures.

Glaucoma↗