PubMed HealthSearch

PubMed · 4945455

[Computer sharing among laboratories--TCLC system].

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

T Ueda, T Miyaji, M Komeoka, Y Yonehara, T Fukuda. 1971. [Computer sharing among laboratories--TCLC system].. https://pubmed.ncbi.nlm.nih.gov/4945455/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Limitations of serum prostate specific antigen in predicting peripheral and transition zone cancer volumes as measured by correlation coefficients.

PURPOSE: We reexamined the relationship between preoperative serum prostate specific antigen (PSA) and prostate cancer volume in 290 patients who underwent radical prostatectomy. MATERIALS AND METHODS: Serum samples from 290 consecutive patients were remeasured with the automated monoclonal-monoclonal Tosoh AIA-600 assay. These values were correlated with individual cancer volume by measuring Pearson correlation coefficients (r). RESULTS: Cancer was noted in the transition zone in 31 patients and in the peripheral zone in 259. Of the peripheral zone cancers 133 (51.4%) were organ confined and 126 (48.6%) were nonorgan confined, including 12 (9.5%) with histologically confirmed lymph node metastasis (stage D1). The 259 peripheral zone cancers had a correlation coefficient with PSA (r = 0.499, p < 0.0001). After distributing the 259 cases into cancer volume groups we found a large overlap in mean preoperative serum PSA, including 65 with 50% or greater Gleason grade 4 or 5 disease (r = 0.508). The correlation coefficients of cancer volume with PSA in 133 organ confined cancers, 114 nonorgan confined cancers without lymph node metastases and 12 nonorgan confined cancers with positive lymph nodes were 0.382, 0.438 and 0.363, respectively. The 31 transition zone cancers showed a correlation coefficient with PSA (r = 0.81). After excluding 2 cases with extreme PSA and cancer volume the correlation coefficient decreased (r = 0.077). CONCLUSIONS: Even when remeasured with an automated monoclonal-monoclonal assay serum PSA alone is unable to predict preoperatively cancer volume or distinguish between organ and nonorgan confined cancer in peripheral and transition zone tumors of the prostate.

Autoanalysis

Determination of the renin inhibitor Ro 42-5892 in human plasma by automated pre-column derivatization, reversed-phase high-performance liquid chromatographic separation and electrochemical detection after post-column irradiation.

The renin inhibitor Ro 42-5892 has been found to be very potent, thereby necessitating a sensitive assay method for the evaluation of its pharmacokinetics in man. We report here the development of a very sensitive and selective HPLC assay for the analysis of this compound in human plasma. Ro 42-5892 was extracted from plasma with dichloromethane, derivatized with 2,4-dinitrofluorobenzene and then chromatographed on a Novapak C18 column (150 x 3.9 mm I.D.) with acetic acid buffer (pH 7)-acetonitrile (100:85). Detection was performed by irradiation at 254 nm, followed by electrochemical oxidation at 550 mV. The extraction recovery of Ro 42-5892 from human plasma (mean 102%) was quantitative. With this method a limit of quantitation of 0.3 ng/ml was achieved. The assay was linear up to 5 ng/ml, had acceptable inter-assay precision (12.2%) and accuracy (9.3%) and was successfully tested for selectivity. This assay was successfully applied to over 250 samples from a pharmacokinetic study in hypertensive patients.

Autoanalysis

Simultaneous determination of terbinafine (Lamisil) and five metabolites in human plasma and urine by high-performance liquid chromatography using on-line solid-phase extraction.

The antimycotic agent terbinafine (Lamisil) and five of its main metabolites were determined simultaneously in human plasma and urine samples by an isocratic HPLC method. The compounds were separated on a phenyl column following on-line solid-phase sample clean-up with a column-switching device. Terbinafine and its metabolites were detected by monitoring the column effluent with UV light at a wavelength of 224 nm. The linear range in plasma was assessed between 0 and 2500 ng/ml for the parent drug and metabolites V, IV and I. The linear response of metabolites III and II was assessed between 0 and 1250 ng/ml. In urine, linearity was assessed between 0 and 10,000 ng/ml for metabolites V, IV, III, II and between 0 and 1000 ng/ml for the parent drug and metabolite I. Quantification limits based on a C.V. < or = 20% and a bias < or = +/- 20% ranged from 20 to 500 ng/ml depending on the compound and the matrix. Inter-day and intra-day variations were similar indicating the ruggedness of the two methods. Due to the considerable differences in hydrophobicity between the compounds, extraction efficiencies ranged from 55 to 100%. Both methods were found to be reproducible and sufficiently sensitive for the evaluation of metabolite pharmacokinetics.

Autoanalysis