Bone conduction calibration: current status.

Abstract

Attempts to specify normal threshold sensitivity by bone conduction have been unsuccessful because of problems in obtaining reliable measurements from commercially available artificial mastoids. Recent design modifications incorporated in the Bruel and Kjaer 4930 artificial mastoids have resulted in greater uniformity among these units. However, the new design has resulted in impedances that are higher than those recommended in current standards. Bone-conduction thresholds referenced to measurements made on B & K 4930 artificial mastoids with the new design were performed on 60 normal listeners by three participating laboratories. The results are reported for consideration in the development of a reference threshold for hearing by bone conduction.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

D D Dirks, S F Lybarger, W O Olsen, B L Billings. 1979. Bone conduction calibration: current status.. https://doi.org/10.1044/jshd.4402.143

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

[An electromechanical model of the middle ear].

A dynamic model of the middle ear and mastoid system was designed in order to evaluate basic principles in tympanometry. The model allows controlled simulation of the exact changes in the ear drum's mass and in intratympanic volume and pressure. The contribution of each of these factors to acoustic impedance was measured. We found that the volume values of static, acoustic compliance were equal to the volume of air in a closed cell. There was good correlation between direct measurement of air pressure in the model cell and indirect pressure measurement by tympanometry. We also demonstrated a difference between mechanical displacement of the drum and its displacement by negative pressure. This demonstration of tympanometry using a middle-ear compatible model enables us to understand its principles and helps in the education of students.

Acoustic Impedance Tests

Diagnostic value of microtympanometry in primary care.

OBJECTIVE: To determine the reliability, validity, and feasibility of a new hand held microtympanometer. DESIGN: Comparison of microtympanometry by two independent observations of a general practitioner and a nurse, and against a validated reference instrument. SETTING: Primary care health centre of a school for the deaf in the United States. SUBJECTS: 111 schoolchildren receiving a regular check up. MAIN OUTCOME MEASURES: Tympanometry with the Grason Stadler 28, classified with a slightly modified Jerger's classification. RESULTS: Interobserver reliability was 0.95 (Cohen's kappa). Results of microtympanometry were highly comparable with results of the reference instrument (likelihood ratio of positive results, 161.2). CONCLUSIONS: The microtympanometer could be used in general practice: it is hand held, child friendly, easy to handle, and accurate.

Acoustic Impedance Tests