PubMed Health⌕ Search

PubMed · 514014

[Statistical analysis of data from glaucoma examinations].

Abstract

Early detection of glaucoma can be achieved through prophylactic screening of population. This leads to a sharp increase in the patients' flow and deprives the physician of a possibility to examine them by routine methods. Such examinations will be feasible if to reduce the procedure time by automation, or to cut the examination program after the analysis of the existing medical programs by mathematical methods. The authors have used the method of linear discriminant functions which permits one on the basis of the medical data statistical analysis to learn the informativeness of diagnostic symptoms and decisive rules to form risk-groups of the patients who need more thorough medical examination. The analysis accomplished has indicated that there is no closely interlaced symptoms. Among most informative there are signs considerably differing in their statistical characteristics. The diagnostic rules proposed in this article provide adequately high accuracy in selection of healthy people groups and, as well, the patients with suspected glaucoma or suffering this disease.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

L Ia Abakumova, A P Nesterov, D I Mitkokh, O P Sushkova. [Statistical analysis of data from glaucoma examinations].. https://pubmed.ncbi.nlm.nih.gov/514014/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Do scleral flap dimensions influence reliability of intraocular pressure control in experimental trabeculectomy?

AIM: To compare the effect on intraocular pressure (IOP) of large vs small scleral flap size during trabeculectomy using adjustable sutures. METHODS: Trabeculectomy operations were performed on nine donor human eyes connected to a constant flow infusion with real-time IOP monitoring. Large scleral flaps (4 x 4 mm, 16 mm(2), n=12) or small scleral flaps (3 x 2 mm, 6 mm(2), n=9) were constructed over 0.76 mm(2) sclerostomies. For each procedure, equilibrium IOP was measured following tight closure with two four-throw adjustable 10-0 nylon sutures. RESULTS: Five scleral flaps were thin or poorly constructed; four of these were in the initial seven procedures, implying learning effect. These had a mean absolute IOP of 7.6 mmHg (range 2.7-12.4 mmHg) and mean relative IOP of 28.3% of baseline (range 10-45.8%) after closure. In the remaining 16 good quality procedures, mean IOP was 1.3 mmHg (range 0-3.4 mmHg) after sclerostomy, confirming minimal outflow resistance before closure. Following flap closure mean IOP was 20 mmHg (SD 4.4, range 15.5-29.3 mmHg) for large (n=8), and 18.7 mmHg (SD 3.6, 15.9-25.8 mmHg) for small (n=8) flaps (unpaired t-test, P=0.26). Mean IOP (% baseline) was 71.6% (SD 8.4, range 60.6-86.6%) and 66% (SD=12.7, 46.8-86.6%) for large and small flap groups, respectively (unpaired t-test, P=0.2). CONCLUSIONS: Well-constructed scleral flaps of both sizes were able to support an average IOP at least two-thirds of baseline, and both had similar absolute IOP levels. Errors in flap construction resulted in loss of IOP control. Smaller flap size does not appear to compromise control of early postoperative IOP using adjustable sutures.

Glaucoma↗