PubMed · 525315
Bone-marrow pressure and bone strength.
Abstract
The pattern of bone-marrow pressure changes differed with the mode of stress application. Intra-medullary pressure remained steady during most of the slow loading. During rapid dynamic loading, however, a slight rise in intra-medullary pressure was observed. Contraction of the femoral muscles also resulted in a greater bone-marrow pressure increase. A correlation of 0.98 (P less than 0.001) between stimulus strength and intra-medullary pressure was obtained. The rise in intra-medullary pressure with femoral muscle contraction is suggested to have a possible role under extreme stresses in living conditions.
Explore related subjects
Keep this discovery
Explore connections, maps & timelines
S Kumar, P R Davis, B Pickles. 1979. Bone-marrow pressure and bone strength.. https://doi.org/10.3109/17453677908989796
Cite the original work for its findings. Save a collection to share your selection of sources.