PubMed HealthSearch

PubMed · 533747

The lung as a filter for microbubbles.

Abstract

A new ultrasonic Doppler device has been used noninvasively over the femoral artery of anesthetized dogs to prove that it can detect carefully calibrated microbubbles of 14--189 micrometers diam when these are infused directly into the aorta. The same evaluated technique has then been employed to detect any bubbles escaping into the arterial system when gas was infused into the venous system either as microbubbles or as a bolus. Results from 18 dogs showed that, under normal conditions, the lungs are a superb filter for bubbles and that any cutoff diameter is less than 22 micrometers. However, bubbles escaped entrapment when the lungs were severely overloaded with gas (20 ml) or were pretreated with a pulmonary vasodilator (aminophylline). The dog preparation and arterial Doppler device appear to be ideal for future studies to determine what other factors might compromise the capability of the lungs to filter microbubbles. Physiological parameters showed dramatic changes when bubbles were detected as escaping into the arterial system by comparison with their effect when retained within the lungs. Changes in respiration profile indicated that they may offer a useful index of the degree of venous embolization and, hence, a warning of impending overload leading to arterial embolization.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

B D Butler, B A Hills. 1979. The lung as a filter for microbubbles.. https://doi.org/10.1152/jappl.1979.47.3.537

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Air saturation of the medium reduces the rate of phosphorylating oxidation of succinate in isolated mitochondria.

Rat brain mitochondria were isolated and their respiration was polarographically measured without contact with air oxygen. Gas-saturated experimental mixtures close to the in vivo partial oxygen pressure (normoxic) were compared with the air-saturated, i.e. hyperoxic, mixtures. The rate of phosphorylating oxidation of added succinate under normoxic conditions was found to be 70-100% higher compared with hyperoxic ones. The addition of succinate dehydrogenase activators results in a more than two-fold stronger stimulation of succinate oxidation under normoxia than under hyperoxia. Thiol group donors are shown to stimulate respiration under hyperoxia and not under normoxia. Hyperoxic conditions prevented oxidation of the low succinate concentrations corresponding to the physiological ones.

Air

Effect of air exposure on nitrogen metabolism in the crab Cancer pagurus.

In C. pagurus exposed to air for 18 h, blood ammonia content decreased within the 2 first hours, then increased at a relatively constant rate (25 microM/h); blood urate content increased at a lower rate (10 microM/h) and a classical blood acidosis was observed. In the cheliped muscle, a transient 22% decrease in GDH activity for ammonia formation and a 48% increase in GDH activity in the reverse reaction (glutamate synthesis) occurred following 6 and 12 h of emersion, respectively. Changes in LDH activity, used as an indicator of anaerobic potential of muscle, were not observed, except for an 18% increase in crabs exposed to air for 24 h. The increase in blood urate content, not known as a response to emersion in decapods, appeared to be different from that observed in response to hypoxia. The relatively low blood ammonia overload and the GDH increased activity for glutamate synthesis suggested that part of the produced ammonia was stored under a bound form in some tissues. The response of C. pagurus to air exposure is discussed on account of the Storey and Storey ('90) theory.

Air