PubMed HealthSearch

PubMed · 537351

Load actions transmitted by implants.

Abstract

The authors consider the mechanics of load transmission between a "conventional" femoral head replacement prosthesis and the shaft of the femur. The three dimensional loading pattern is now well known and the changes of interface stressing through a load cycle is considered. The actual stress situation depends on features of the implantation technique, the mechanical properties of all the materials involved in the relevant friction coefficient. From analysis of systems at the extreames of these limits, the authors suggest probable service conditions.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

N Berme, J P Paul. 1979. Load actions transmitted by implants.. https://doi.org/10.1016/0141-5425(79)90164-x

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Comparison of helical and serial CT with regard to three-dimensional imaging of musculoskeletal anatomy.

To test the hypothesis that helical computed tomographic (CT) scans provide three-dimensional images as good as or better than those provided by serial CT, two objects were used to study the effects of helical CT: an angled cylindrical bone phantom and a human cadaveric femur specimen with a simulated fracture 1 mm wide. Both objects were immersed in a water bath, and a series of helical and serial CT scans were obtained with various parameters. Volumetric rendering was applied to the resultant data sets to create three-dimensional images, which three radiologists reviewed in a blinded manner to rate their fidelity, accuracy, and diagnostic usefulness. As expected, the images obtained with thin collimation and small intersection spacing or slow table movement were considered superior. Helical and serial CT data acquired with similar parameters were similar in quality, but helical CT is approximately five times faster than serial CT; hence, it is possible to use thinner collimation and obtain more sectional data with helical CT.

Femur

A three-dimensional morphometrical study of the distal human femur.

The objective of this paper is to present a method to describe the three-dimensional variations of the geometry of the three portions forming the distal part of the human femur: the medial and lateral femoral condyles and the intercondylar fossa. The contours of equally spaced sagittal slices were digitized on the distal femur to determine its surface topography. Data collection was performed using a digitizer system which utilizes low-frequency, magnetic field technology to determine the position and orientation of a magnetic field sensor in relation to a specified reference frame. The generalized reduced gradient optimization method was used to reconstruct the profile of each slice utilizing two primitives: straight-line segments and circular arcs. The profile of each slice within the medial femoral condyle was reconstructed using two circular arcs: posterior and distal. The profile of each slice within the lateral femoral condyle was reconstructed using three circular arcs: posterior, distal and anterior. Finally, the profile of each slice within the intercondylar fossa was reconstructed using two circular arcs: proximal-posterior and anterior, and a distal-posterior straight-line segment tangent to the proximal-posterior circular arc. Combining the data describing the profiles of the different slices forming the distal femur, the posterior portions of each of the medial and lateral femoral condyles were modelled using parts of spheres having an average radius of 20 mm. The anterior portion of the lateral condyle was approximated to a right cylinder having its circular base parallel to the sagittal plane with an average radius of 26 mm. The anterior portion of the intercondylar fossa was modelled using an oblique cylinder having its circular base parallel to the sagittal plane with an average radius of 22 mm. Furthermore, it is suggested that the distal portion of the lateral femoral condyle could be modelled using parts of two oblique cones while the distal portion of the medial femoral condyle could be modelled using a part of a single oblique cone, all cones having their circular bases parallel to the sagittal plane. It is also suggested that the posterior portion of the intercondylar fossa could be modelled using two oblique cones: a proximal cone having its base parallel to the sagittal plane and a distal cone having its base parallel to the frontal plane.

Femur