PubMed HealthSearch

PubMed · 673363

[Materials for replacing bone defects and joining bones].

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

O N Gudushauri, B L Solomianskiĭ, D A Omiadze. 1978. [Materials for replacing bone defects and joining bones].. https://pubmed.ncbi.nlm.nih.gov/673363/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Preparation of TEM foils from Nb-10 a/o Si.

Ductile phase toughened composites contain phases with significantly different physical properties. Consequently, these phases thin at different rates depending on the sample preparation procedure. A new TEM foil preparation method for the ductile phase toughened Nb-10 a/o Si material has been developed. The method involves chemical thinning in a 70% nitric acid/30% hydrofluoric acid solution followed by electropolishing in a 12.5% sulfuric acid/87.5% methanol electrolyte at -40 degrees C. This procedure for making TEM foils results in large thin areas with the minimum of artifacts. Mechanical grinding of a sample followed by either ion milling, dimpling, or electropolishing produced foils with large electron transparent areas, but with uncharacteristic features of the original Nb-10 a/o Si alloy microstructure. These artifacts were identified as dislocations, surface mottling, and antiphase domains.

Alloys

Acoustic emission during fatigue of porous-coated Ti-6Al-4V implant alloy.

Acoustic emission (AE) events and event intensities (e.g., event amplitude, counts, duration, and energy counts) were recorded and analyzed during fatigue loading of uncoated and porous-coated Ti-6Al-4V. AE source location, spatial filtering, event, and event intensity distributions were used to detect, monitor, analyze, and predict failures. AE provides the ability to spatially and temporally locate multiple fatigue cracks, in real time. Fatigue of porous-coated Ti-6Al-4V is governed by a sequential, multimode fracture process of: transverse fracture in the porous coating; sphere/sphere and sphere/substrate debonding; substrate fatigue crack initiation; slow and rapid substrate fatigue crack propagation. Because of the porosity of the coating, the different stages of fracture within the coating occur in a discontinuous fashion. Therefore, the AE events generated are intermittent and the onset of each mode of fracture in the porous coating can be detected by increases in AE event rate. Changes in AE event rate also correspond to changes in crack extension rate, and may therefore be used to predict failure. AE offers two distinct advantages over conventional optical and microscopic methods of analyzing fatigue cracks--it is more sensitive and it can determine the time history of damage progression. The magnitude of the AE event intensities increased with increasing stress. Failure mechanisms are best differentiated by analyzing AE event amplitudes. Intergranular fracture and microvoid coalescence generated the highest AE event amplitudes (100 dB), whereas, plastic flow and friction generated the lowest AE event amplitudes (55-65 dB). Fractures in the porous coating were characterized by AE event amplitudes of less than 80 dB.

Alloys

Enhanced ingrowth of porous-coated CoCr implants plasma-sprayed with tricalcium phosphate.

Tricalcium phosphate (TCP) is an osteo-conductive bioceramic which, when applied to a porous-coated prosthesis, may enhance osseous ingrowth and mechanical stability. TCP plasma-sprayed and unsprayed porous-coated tibial intramedullary rods were bilaterally implanted in seven adult rabbits. All rabbits were killed at 12 weeks. Pull-out tests were performed on 4 rabbits while all were evaluated histologically for osseous response and adverse tissue reaction. TCP-sprayed implants showed significantly greater osseous ingrowth in comparison to unsprayed implants. Neither implant type exhibited adverse tissue reactions. Average pull-out strengths were 69 lb for treated rods and 72 lb for controls (p greater than 0.05); quality of fit for all pull-out specimens except one was deemed poor. We conclude that plasma-sprayed TCP enhances osseous ingrowth into porous-coated devices. However, our data further suggest that enhanced ingrowth may not always lead to enhanced fixation.

Alloys