PubMed · 6745429
Competitive solid-phase immunoassay of testosterone using time-resolved fluorescence.
Abstract
A competitive solid-phase immunoassay for the determination of testosterone in serum samples using time-resolved fluorescence is described. The solid phase is a testosterone-3-(O-carboxymethyl)-oxime-ovalbumin conjugate coated to polystyrene microtiter strips. Europium-labelled polyclonal and monoclonal antibodies against testosterone-3-(O-carboxymethyl)-oxime-bovine serum albumin were compared. Their behavior was quite similar although the polyclonal antibody was more sensitive, giving a detection limit of 15 fmol testosterone per assay. Correlation with RIA was very good (r = 0.982 and y = -0.150 + 0.969x).
Explore related subjects
Keep this discovery
Explore connections, maps & timelines
E Bertoft, J U Eskola, V Näntö, T Lövgren. 1984-07-23. Competitive solid-phase immunoassay of testosterone using time-resolved fluorescence.. https://doi.org/10.1016/0014-5793(84)81049-2