PubMed Health⌕ Search

PubMed · 6801600

Composite myocutaneous flaps.

Abstract

In this past few years myocutaneous (MC) flaps have, to a large extent, replaced other flaps. Because of axial blood supply, they may be used without delay. The MC flaps, useful in head and neck reconstruction, are based on the latissimus dorsi, the pectoralis major, the sternomastoid, and the trapezius. All have discrete independent vasculature that acts as a pedicle for the muscle and skin flap. The sternomastoid MC flaps have limited range and only special areas of usefulness. The latissimus dorsi flap, because it requires special positioning of the patient, has not been as popular as the pectoralis major flap, but both have excellent blood supplies and will reach almost any area of the face and neck to fill defects and cover internal or external surfaces. In addition, the pectoralis major MC flap may be able to carry a segment of rib as a bone graft. The trapezius MC flap does not have as great a range as the others and has a long vascular pedicle that must be carefully handled, but it has the distinct advantage of being able to carry viable bone from the scapular spine to the mandible.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

M J Shapiro. Composite myocutaneous flaps.. https://doi.org/10.1177/019459988108900618

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Multidetector CT and dentascan software: dosimetric evaluation and technique improvement.

PURPOSE: The development of new operative techniques in oral and maxillofacial surgery within the last few years has led to an increasing demand for Dentascan examination, also in paediatric patients. It is necessary to modify acquisition parameters to reduce the absorbed dose. The aim of this study was to define a Dentascan protocol in which a reduced X-ray dose could be used. MATERIALS AND METHODS: Dosimeters were applied to the eyes, mouth, parotid glands, thyroid and back of the neck of an anthropomorphic Plexiglas phantom that underwent multidetector computed tomography (MDCT) Dentascan examinations. Both 120kV and 80 kV were used to study the mandibular and maxillary arches. RESULTS: Examinations obtained with the 80 kV protocol showed a ten-fold reduction in the absorbed dose, without affecting image quality. CONCLUSIONS: We suggest a Dentascan protocol that reduces the X-ray dose administered to the patient while ensuring the same high diagnostic accuracy.

Head↗