Analysis of errors in parameter estimation with application to physiological systems.

Abstract

The accuracy of parameter estimation applied to physiological systems is analyzed. The method of analysis is applicable to procedures utilizing minimization of squared output error and a nonlinear dynamic system model. Three major sources of estimation error are described: 1) measurement error, 2) modeling error, and 3) optimization error. Measurement errors affect values used for the system output, the model input, and nonestimated parameters of the model. Modeling errors are due to failure to adequately describe the structure of the system and to numerical errors that occur in the digital computer solution of the model equations. Linearization by use of Taylor series expansions in the region of the nominal solution is used to obtain an expression for the covariance matrix of the parameter estimates in terms of the covariance matrix of each error source. The analysis is applied to the example of cardiac output estimation from respiratory measurements. The results demonstrate that an analysis of system identifiability is not sufficient to ensure usable estimates and that systematic error analysis is essential for assessing the usefulness of parameter estimation techniques.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

T M Grove, G A Bekey, L J Haywood. 1980. Analysis of errors in parameter estimation with application to physiological systems.. https://doi.org/10.1152/ajpregu.1980.239.5.r390

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Beat-to-beat changes in stroke volume precede the general circulatory effects of mechanical ventilation: a case report.

BACKGROUND: The haemodynamic as well as the ventilatory consequences of mechanical ventilation can be harmful in critically ill neonates. Newly developed ventilatory lung protective strategies are not always available immediately and in an acute situation the haemodynamic changes caused by mechanical ventilation can affect the oxygen delivery considerably. We report the case of a male neonate who was treated with conventional pressure-controlled mechanical ventilation because of respiratory distress and progressive respiratory acidosis resulting from meconium aspiration. Because of poor arterial oxygenation despite 100% inspired oxygen and increased ventilator settings, echocardiography was performed to exclude central haemodynamic reasons for low oxygen delivery. METHOD: Doppler echocardiography was used for the measurement of stroke volume and cardiac output. Pulse oximetry and aortic blood pressure were monitored continuously. RESULTS: Echocardiography revealed no cardiac malformations or signs of persistent fetal circulation. When inspiratory pressures and duration were increased, beat-to-beat variation in stroke volume preceded decay in cardiac output. Stroke volume variations and oxygen saturation values guided ventilator settings until extracorporal membrane oxygenation could be arranged for. After recovery and discharge 4 weeks later the boy is progressing normally. CONCLUSION: Because oxygen delivery is dependent on both blood flow and arterial oxygen content, measurement of cardiac output as well as left heart oxygen saturation is a useful guide to optimizing oxygen delivery. This case report demonstrates how Doppler echocardiographic monitoring of beat-to-beat changes in stroke volume can be used to detect early negative haemodynamic effects of increased mechanical ventilation settings before cardiac output is affected.

Cardiac Output↗