PubMed Health⌕ Search

PubMed · 7555158

Left ventricular systolic performance during acute hypoxemia.

Abstract

STUDY OBJECTIVE: Although some of the cardiovascular responses to hypoxemia are well described, effects on myocardial contractility have not been defined. Such effects are readily assessed by noninvasive techniques and we have therefore evaluated Doppler-phonocardiographic parameters of systolic left ventricular contractility in normal humans rendered hypoxemic. DESIGN: Eight healthy male volunteers were studied. Parameters were measured after resting to achieve baseline haemodynamics, after 20 min moderate hypoxemia (SaO2 85 to 90%), and after a further 20 min of severe hypoxemia (SaO2 75 to 80%). Hypoxemia was induced by breathing a variable N2/O2 mixture. MEASUREMENTS: Pulsed-wave Doppler analysis of ascending aortic blood flow was combined with phonocardiography to measure indices of systolic left ventricular function at baseline and at the end of each period of hypoxemia. RESULTS: There was a significant, dose-related increase in cardiac output in response to hypoxemia, from 5.5 +/- 0.26 L/min at baseline to 6.1 +/- 0.08 L/min during moderate hypoxemia and to 7.0 +/- 0.23 L/min during severe hypoxemia. Likewise, heart rate increased significantly in dose-related fashion although stroke volume was not affected by either level of hypoxemia. Hypoxemia had no significant effects on systolic or diastolic blood pressures, but caused a significant reduction in systemic vascular resistance. Aortic peak and mean acceleration and acceleration time were not affected by moderate or severe hypoxemia. Although the systolic time intervals measured shortened significantly during severe hypoxemia, these were no longer significant when appropriate corrections were made for heart rate. CONCLUSIONS: Although cardiac output increases during hypoxemia, this is due to increases in heart rate but not to any effect on stroke volume. Parameters of left ventricular systolic function and myocardial inotropic state were also not affected by severe hypoxemia. Systolic left ventricular function and myocardial contractility are thus well preserved in normal humans during hypoxemia.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

R I Cargill, D G Kiely, B J Lipworth. 1995. Left ventricular systolic performance during acute hypoxemia.. https://doi.org/10.1378/chest.108.4.899

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

The effect of acute pain crisis on exhaled nitric oxide levels in children with sickle cell disease.

Exhaled nitric oxide (FE(NO)) has been shown to be decreased in children with sickle cell disease. We sought to evaluate the effect of sickle cell vaso-occlusive crisis (VOC) on FE(NO) levels. We measured FE(NO) levels in 42 children with sickle cell disease, 29 in their baseline health and 13 during an acute VOC. There was no difference in FE(NO) levels between children at baseline (15.12 +/- 9.32 ppb) and those during an acute VOC (15.68 +/- 7.26 ppb; P = 0.794). FE(NO) is not a useful marker of acute VOC in children with sickle cell disease.

Acute Disease↗

[Megadolichobasilar anomaly causing acute deafness with vertigo].

Megadolichobasilar anomaly, a dilatant arteriopathy of the basilar artery attributable to chronic arterial hypertension, can cause cranial nerve compression syndromes of the cerebellopontine angle or infarcts of the vertebrobasilar circulation. In this paper, we report on a patient with known megadolichobasilar anomaly and a partially thrombosed fusiform aneurysm of the basilar artery, who presented with acute-onset vertigo and subsequent deafness due to thromboembolic occlusion of the labyrinthine artery. Because of the vascular origin of the patient's symptoms, his vertigo disappeared over time while the deafness persisted.

Acute Disease↗

Retrieval of a leaflet escaped in a Tri-technologies bileaflet mechanical prosthetic valve.

The escape of the prosthetic heart valve disc is one of the causes of prosthetic dysfunction that requires emergency surgery. The removal of the embolized disc should be carried out because of the risk of a progressive extrusion on the aortic wall. Several imaging techniques can be used for the detection of the missing disc localization. In this report we describe a 32-year-old man who underwent mitral valve replacement with a Tri-technologies bileaflet valve three years ago, and was admitted in cardiogenic shock. Transesophageal echocardiography showed acute-onset massive mitral regurgitation. The patient underwent emergency replacement of the prosthetic valve. Only one of the two leaflets remained in the removed prosthetic valve. The missing leaflet could not be found within the cardiac cavity. The abdominal fluoroscopic study and plain radiography were unable to detect the escaped leaflet. The abdominal computed tomography scan and the ultrasound showed the escaped leaflet in the terminal portion of the aortic bifurcation. To retrieve the embolized disc laparotomy and aortotomy were performed three months later. The escaped leaflet shows a fracture of one of the pivot systems caused by structural failure. This kind of failure mode is usually the result of high stress concentration.

Acute Disease↗