[Bromocriptine-induced pleuropneumopathy].

Abstract

A 64-year-old man was diagnosed to have Parkinson's disease when aged 42 years and since then has been treated with levodopa and benserazide (up to 875 mg daily). Bromocriptine (up to 35 mg daily) was added to the medication 9 years ago. 3 1/2 years ago he developed exertional dyspnoea (NYHA class II-III) and lost 5 kg in weight. Chest radiography demonstrated pleural effusion and interstitial pulmonary changes in both lung bases. Erythrocyte sedimentation rate was 37 mm in the first hour and the white cell count 10,400/microliters. Extensive tests failed to find malignant tumour or any infectious-inflammatory condition. As it was suspected that the pleuropulmonary changes were associated with the bromocriptine intake, it was discontinued and biperiden and selegiline substituted for it. The pleural effusion regressed almost completely within 8 weeks, and the laboratory tests pointing to inflammation disappeared completely. Clinical, biochemical and radiological tests have remained normal for the last 3 years. The clinical course makes a causal relationship between bromocriptine intake and the pleuropulmonary changes highly probable.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

P A Schmid, T Suter, R Speich, F Eberli, P Greminger. 1994-11-11. [Bromocriptine-induced pleuropneumopathy].. https://doi.org/10.1055/s-2008-1058870

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Simultaneous determination of benserazide and levodopa by capillary electrophoresis-chemiluminescence using an improved interface.

A capillary electrophoresis coupling with indirect chemiluminescence detection method for the simultaneous determination of benserazide and levodopa has been developed. The detection interface was improved to simplify the capillary electrophoresis-chemiluminescence (CE-CL) system and the features of this improved interface were illustrated in this paper. The CE-CL conditions for the simultaneous determination of benserazide and levodopa were optimized. Under the optimal conditions, the CL intensity was linear with concentrations of levodopa in the range of 1.0 to 100.0 microg ml(-1), and benserazide in the range of 10.0 to 1,000 microg ml(-1), respectively. The detection limits (S/N=3) in turn were 1.85 microg ml(-1) for BS and 0.12 microg ml(-1) for L-dopa with relative standard deviations of less than 3%. The proposed method has been successfully applied to the determination of benserazide and levodopa in medopar tablets and spiked urine samples, demonstrating the feasibility and reliability of the proposed method.

Benserazide↗

Simultaneous determination of levodopa and benserazide by stopped-flow injection analysis and three-way multivariate calibration of kinetic-spectrophotometric data.

The simultaneous determination of levodopa and benserazide in pharmaceutical formulations is described, based on the application of multidimensional partial least-squares regression to the kinetic-spectrophotometric data provided by diode-array detection within a stopped-flow injection method where analytes react with periodate. Flow injection parameters were adequately optimized. Accurate analysis is performed with no sample pre-treatment steps, and with minimum experimental effort. Satisfactory recovery results were obtained on a number of synthetic and commercial samples, in the latter case including the comparison with liquid chromatography measurements.

Benserazide↗