Occupational needs and evaluation methods for cold protective clothing.

Abstract

The aim of the study was to evaluate the needs for and properties of the occupational cold protective clothing with different methods and the risks related to work in cold conditions from the point of view of occupational hygiene and clothing physiology. The thermal insulation of textile materials and clothing was investigated with the equipment, methods and parameters developed especially in cold and windy conditions in dynamic and steady states. Also the simulation and calculation of results were done and compared to the measurements. The cold exposure from the point of occupational hygiene was evaluated in working life to evaluate the risk of cooling and frostbite and utility ranges of clothing. The function of the sweating hot plate constructed and cylinder in the wind tunnel could be regarded adequate for the evaluation of winter clothing with good precision, stability and repeatability. The measured total thermal resistance was mainly dependent on, and operative thermal resistance independent of, temperature. The operative thermal resistance was also very sensitive to errors in measurement procedures. The heat flow usually evaluated by thermal and water vapour resistance could be substituted for total thermal resistance. Both the measurements and theories showed that, in addition to air permeability, also the ambient temperature, air gaps, contact layers and thickness of clothing were important parameters. Increase of wind (1...8 m/s) decreased the total thermal resistance and mass transfer up to 60% depending on conditions. The comparison of calculation models with material measurements proved the value of the simulation models. The reason for differences between the methods was mainly due to changes in water vapour resistance in the cold. The heat flux method was exact enough in the evaluation of the insulation of clothing in the field but in sweating conditions the condensation and evaporation must be taken into consideration. In the case of heat debt in the cold the heat flux method gave smaller values than the thermometric method. The material measurements diverged logically from the clothing measurements but material methods had a better capability to analyze the differences of material ensembles. In the evaluation of body cooling and performance degradation in outdoor work the physiological recommendations given were temporarily exceeded in 70% of the cases measured (N = 143). The cold problems already occurred in temperatures from 0 to 10 degrees C. The reasons for the cold problems were related to the type of work e.g. wind to the face and long exposure to the feet caused frostbite.(ABSTRACT TRUNCATED AT 400 WORDS)

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

H Anttonen. 1993. Occupational needs and evaluation methods for cold protective clothing.. https://pubmed.ncbi.nlm.nih.gov/8048995/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Thermographic assessment of inferior alveolar nerve injury in patients with dentofacial deformity.

PURPOSE: The purpose of this study was to evaluate the injury and recovery of the inferior alveolar nerve in orthognathic patients at 1 and 4 weeks after surgery using electronic thermography. MATERIALS AND METHODS: Twenty subjects with Class III dentofacial deformity were studied. All patients underwent bilateral sagittal split ramus osteotomy. To image the temperature of the face, 1 anteroposterior view and 1 lateral view were taken from both the right and left sides. Similar images were taken at 1 and 4 weeks after surgery. The control was the presurgical temperature of the 20 patients who showed unilateral or bilateral nerve damage after surgery. RESULTS: In the patients with unilateral nerve damage (n = 14), on the anteroposterior views, the temperatures of the mentum on the 2 sides differed by 0.64 degrees C at 1 week after surgery, and the difference decreased to 0.23 degrees C at 4 weeks after surgery. On the lateral images, the differences in temperature between the mentum areas were 0.10 degrees C at 1 week and 0.27 degrees C at 4 weeks after surgery. In the patients with bilateral nerve injury (n = 6), on the anteroposterior views, the temperatures of the mentum on the 2 sides differed by 0.20 degrees C at 1 week after surgery and 0.13 degrees C after 4 weeks. On the lateral views, the differences were 0.18 degrees C at 1 week and 0.34 degrees C at 4 weeks after surgery. Using the repeated measurement analysis method, the anteroposterior view showed statistically significant results in the patients with unilateral nerve damage. CONCLUSION: The infrared body temperature method is an objective method that can be applied as a supplemental diagnostic method for inferior alveolar nerve injury.

Body Temperature↗

The ingestible telemetric body core temperature sensor: a review of validity and exercise applications.

An ingestible telemetric temperature sensor for measuring body core temperature (Tc) was first described 45 years ago, although the method has only recently gained widespread use for exercise applications. This review aims to (1) use Bland and Altman's limits of agreement (LoA) method as a basis for quantitatively reviewing the agreement between intestinal sensor temperature (Tintestinal), oesophageal temperature (Toesophageal) and rectal temperature (Trectal) across numerous previously published validation studies; (2) review factors that may affect agreement; and (3) review the application of this technology in field-based exercise studies. The agreement between Tintestinal and Toesophageal is suggested to meet our delimitation for an acceptable level of agreement (ie, systematic bias <0.1 degrees C and 95% LoA within +/-0.4 degrees C). The agreement between Tintestinal and Trectal shows a significant systematic bias >0.1 degrees C, although the 95% LoA is acceptable. Tintestinal responds less rapidly than Toesophageal at the start or cessation of exercise or to a change in exercise intensity, but more rapidly than Trectal. When using this technology, care should be taken to ensure adequate control over sensor calibration and data correction, timing of ingestion and electromagnetic interference. The ingestible sensor has been applied successfully in numerous sport and occupational applications such as the continuous measurement of Tc in deep sea saturation divers, distance runners and soldiers undertaking sustained military training exercises. It is concluded that the ingestible telemetric temperature sensor represents a valid index of Tc and shows excellent utility for ambulatory field-based applications.

Body Temperature↗