PubMed Health⌕ Search

PubMed · 8134601

Stair-step artifacts in three-dimensional helical CT: an experimental study.

Abstract

PURPOSE: Stair-step artifacts in helical computed tomography (CT) are associated with inclined surfaces in longitudinal sections. The authors investigated the origin and the characteristics of the artifacts. MATERIALS AND METHODS: A cone phantom and a skull were dry-scanned with a helical CT scanner, and images were reconstructed by using the half-scan interpolation algorithm with combinations of detector collimation (1 and 5 mm), table feed (1, 2, 5, and 10 mm), and reconstruction interval (1, 2, 5, and 10 mm). RESULTS: Stair-step artifacts were perceived in most instances. Stair-step artifacts arose from two sources: large reconstruction intervals and asymmetric helix interpolation, forming isoclosed curves and spirallike patterns in three-dimensional axial views, respectively. CONCLUSION: To eliminate the stair-step artifacts, both the collimation and the table feed should be less than the longitudinal dimension of the important feature on inclined surfaces, and the reconstruction interval should be less than the table feed. Adaptive interpolation may correct the artifacts.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

G Wang, M W Vannier. 1994. Stair-step artifacts in three-dimensional helical CT: an experimental study.. https://doi.org/10.1148/radiology.191.1.8134601

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Striping artifact removal in VisiumHD data through nuclear counts modeling.

MOTIVATION: 10x Genomics VisiumHD enables spatial transcriptomics at 2 µm × 2 µm resolution but exhibits slide-specific, non-periodic striping artifacts due to lane-width variability. These multiplicative row/column effects distort bin total counts and can bias downstream analyses. The state-of-the-art destriping approach is the normalization procedure used as a preprocessing step in bin2cell; it applies sequential high-quantile row- then column-wise normalization, which is asymmetric and can introduce edge effects/macro-stripes and distortions of large-scale total-count structure. RESULTS: We propose a statistical destriping approach that leverages nuclei segmentation from the co-registered H&E image. Assuming transcript abundance is constant within each nucleus, we model bin counts with a negative binomial distribution whose mean is a product of a nucleus-specific concentration and row- and column-specific stripe-factors reflecting lane-width variation. We fit all parameters in a generalized linear modeling framework with cross-validated regularization on stripe-factors and iterative dispersion estimation, and use the fitted parameters to correct the observed counts into a destriped image. On synthetic data with known ground truth, our method improves stripe-factor estimation accuracy and reduces error in corrected counts relative to bin2cell and bin2cell-derived baselines. Across four public VisiumHD slides, it consistently lowers striping intensity while substantially better preserving biological signal present in the large-scale global count structure and avoiding the artifacts introduced by other methods. AVAILABILITY AND IMPLEMENTATION: All source code and links to publicly available data used for this study are available at https://github.com/paolamalsot/destriping-GLM.

Artifacts↗

Impairment of echocardiographic acoustic window caused by breast implants.

Cosmetic breast implants are increasing in popularity. The presence of a breast implant overlying the anterior mediastinal space as a cause of impairment of the echocardiographic acoustic window has not been described previously. Here, we report three cases with significant impairment of echocardiographic acoustic window caused by breast implants. Clinicians should be aware of this interference and women should be informed of this dilemma before considering this cosmetic surgery.

Artifacts↗