Color flow imaging.

Abstract

The most recent technology change in diagnostic ultrasound is color flow imaging (CFI), which is a merging of gray-scale and motion-detection processing to produce an image that depicts soft tissue in gray scale and blood flow in color. Currently, CFI comes in three forms: synchronous signal processing, asynchronous signal processing, and time domain analysis. The first two employ Doppler-based principles, and the third uses direct measurements of blood flow displacement in the image. All three forms of CFI break the image into multiple sampling segments and process amplitude and motion information. A functional understanding of these technologies helps define and extend their roles in radiology as imaging tools.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

R L Powis. 1994. Color flow imaging.. https://doi.org/10.1148/radiographics.14.2.8190964

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Epicardial coronary arteries are not adequately sized in hypertensive patients.

OBJECTIVES: This study sought to compare coronary artery dimensions in hypertensive patients and normal subjects. BACKGROUND: Myocardial oxygen demand at rest and corresponding coronary blood flow are the main determinants of large coronary artery dimensions in humans. Coronary diameters are increased in aortic valve disease. METHODS: Left main, proximal and distal left anterior descending and proximal circumflex coronary artery diameters were measured by quantitative angiography in 10 control subjects (group 1) and 26 untreated hypertensive patients, 12 without (group 2a) and 14 with (group 2b) left ventricular hypertrophy. All patients had normal cholesterol levels and angiographically normal coronary arteries. Measurements were made at baseline and after 2 mg of intracoronary isosorbide dinitrate to obtain maximal dimensions of vessels. Coronary flow velocity was measured in the distal left anterior descending coronary artery by Doppler ultrasound. RESULTS: Despite a higher rate-pressure product in hypertensive patients, all segment diameters were slightly but not significantly higher at baseline in group 2b than in groups 1 and 2a. Diameters were similar in the three groups after isosorbide dinitrate. Conversely, coronary flow velocity was significantly higher in hypertensive patients than in group 1 either at baseline (10.4 +/- 2.2 [mean +/- SD] cm/s [group 2a] and 12.8 +/- 2.4 cm/s [group 2b] vs. 6.5 +/- 2.0 cm/s [group 1], all p < 0.001) or after isosorbide dinitrate (6.8 +/- 2.8 cm/s [group 2a] and 7.8 +/- 2.1 cm/s [group 2b] vs. 3.7 +/- 0.8 cm/s [group 1], p < 0.01 and p < 0.001, respectively). CONCLUSIONS: Despite an elevated myocardial oxygen demand, maximal dimensions of large coronary arteries are not increased in hypertensive patients, resulting in an elevated coronary flow velocity that may increase longitudinal shear stress at the endothelial surface. This elevated flow velocity might be an important determinant in the pathogenesis of atherosclerosis in hypertensive patients.

Blood Flow Velocity

Effect of dual-chamber pacing on systolic and diastolic function in patients with hypertrophic cardiomyopathy. Acute Doppler echocardiographic and catheterization hemodynamic study.

OBJECTIVES: This study sought to evaluate prospectively the acute hemodynamic effect of dual-chamber pacing by using a combined hemodynamic approach of high fidelity pressure and Doppler velocity measurements. BACKGROUND: Dual-chamber pacing has been proposed recently as an alternative in the symptomatic treatment of patients with hypertrophic obstructive cardiomyopathy. Although early reports documented a decrease in left ventricular outflow tract gradient and symptomatic improvement, questions remain about the hemodynamic effects of dual-chamber pacing on systolic and diastolic function. METHODS: Twenty-nine patients with hypertrophic cardiomyopathy underwent a combined cardiac catheterization and Doppler echocardiographic study during normal sinus rhythm and P-synchronous pacing at various atrioventricular (AV) intervals. High fidelity pressure measurements of left ventricular inflow and left atrial pressures, ascending aortic pressure, thermodilution cardiac output and Doppler mitral flow velocity curves were obtained to evaluate both systolic and diastolic left ventricular function. RESULTS: During AV pacing at the shortest delay of 60 ms, there was a significant decrease in cardiac output (p < 0.05) and peak positive dP/dt (p < 0.05), an increase in mean left atrial pressure (p < 0.05) and a prolongation of tau, the time constant of relaxation (p < 0.05), compared with that during normal sinus rhythm. During pacing at the optimal AV delay (longest AV interval with pre-excitation), there was a similar trend, with deterioration in both systolic and diastolic function variables but of lesser magnitude than that during pacing at the shortest AV intervals. The deterioration in both systolic and diastolic function was present in 21 patients with and 8 without left ventricular outflow obstruction. There was a modest decrease in left ventricular outflow tract gradient from 73.3 +/- 45.0 (mean +/- SD) to 61.3 +/- 40.5 mm Hg (p = 0.03) during dual-chamber pacing at the optimal AV delay compared with that during normal sinus rhythm. CONCLUSIONS: The acute effect of pacing the right atrium and ventricle may be detrimental to both systolic and diastolic function of the left ventricle, particularly at the short AV intervals. Further studies of the long-term effects of dual-chamber pacing in carefully performed randomized studies are needed.

Blood Flow Velocity