PubMed Health⌕ Search

PubMed · 8476346

A comparison between data analysis methods concerning particle size distributions obtained by mastication in man.

Abstract

Three mixtures of chewed food particles (coarse, medium and fine) were quantified by measuring the particle sizes with an optical scanning device. The particle sizes were described by three different particle-size distributions: a cumulative volume, a volume and a number distribution. The median particle size was determined from each of the distribution functions. Suitability for characterizing a mixture of chewed food particles was tested, showing that the median particle size as obtained from a cumulative volume (or weight) distribution should be preferred. It was shown to be the most sensitive measure for characterizing mixtures of chewed food.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

A van der Bilt, J H Abbink, F Mowlana, M R Heath. 1993. A comparison between data analysis methods concerning particle size distributions obtained by mastication in man.. https://doi.org/10.1016/0003-9969(93)90202-w

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

A method to quantitatively detect H-ras point mutation based on electrochemiluminescence.

Conventional methods for point mutation detection are usually multi-stage, laborious, and need to use radioactive isotopes or other hazardous materials, and the assay results are often semi-quantitative. In this work, a protocol for quantitative detection of H-ras point mutation was developed. Electrochemiluminescence (ECL) assay was coupled with restriction endonuclease digestion directly from PCR products. Only the wild-type amplicon containing the endonuclease's recognition site can be cut off, and thus cannot be detected by ECL assay. Using the PCR-ECL method, 30 bladder cancer samples were analyzed for possible point mutation at codon 12 of H-ras oncogene. The results show that the detection limit for H-ras amplicon is 100 fmol and the linear range is more than three orders of magnitude. The point mutation was found in 14 (46.7%) out of 30 bladder cancer samples. The experiment results demonstrate that the PCR-ECL method is a feasible quantitative approach for point mutation detection due to its safety, high sensitivity, and simplicity.

Calibration↗

Validated assay for the determination of markers of illicit heroin in urine samples for the control of patients in a heroin prescription program.

A fully validated procedure for the simultaneous determination of morphine (MOR), morphine-3-glucuronide (M3G), morphine-6-glucuronide (M6G), 6-acetylmorphine (6AM), codeine (COD), codeine-6-glucuronide (C6G), acetylcodeine (AC), noscapine (NOS) and papaverine (PAP) based on liquid chromatography followed by electrospray mass spectrometry applying multiple reaction monitoring (LC-ESI-MS/MS) in urine samples is described. The extraction was carried out on a Zymark Rapid Trace Workstation using C18 solid-phase extraction cartridges. The separation was performed in 19 min on an Agilent 1100 HPLC system, using a Phenomenex C18 AQUA column (4 microm, 150 mm x 2 mm), which is coupled with an Applied Biosystems API 2000 mass spectrometer. Deuterated analogues were used as internal standards. The limits of detection were in the range of 0.1 ng/ml (PAP) to 7.4 ng/ml (M6G), the coefficients of correlation were higher than 0.996, the precisions ranged from 3% to 12% and the absolute recoveries were between 45% (M3G) and 98% (MOR). Analyses of samples from patients of a heroin prescription program demonstrated the usefulness of the procedure for the analytical differentiation between prescribed synthetic heroin (diamorphine) use and non-prescription heroin abuse on the basis of urine analysis. After the ingestion of pharmaceutical heroin only general markers for heroin use were detected, which are MOR, M3G, M6G and 6AM, respectively. When illicit heroin was abused, additionally to further general markers (COD, C6G) specific markers for non-prescription heroin abuse (AC, NOS, PAP) were found. However, it must be kept in mind that only AC may be regarded as absolute specific marker of non-prescription heroin, because all other compounds may appear in urine after ingestion of opiate alkaloids containing medicines or foods (e.g. poppy seeds). Therefore, patients of a heroin prescription program should be advised not to ingest such products.

Calibration↗

A dynamic supraclavicular field-matching technique for head-and-neck cancer patients treated with IMRT.

PURPOSE: The conventional single-isocenter and half-beam (SIHB) technique for matching supraclavicular fields with head-and-neck (HN) intensity-modulated radiotherapy (IMRT) fields is subject to substantial dose inhomogeneities from imperfect accelerator jaw/MLC calibration. It also limits the isocenter location and restricts the useful field size for IMRT. We propose a dynamic field-matching technique to overcome these limitations. METHODS AND MATERIALS: The proposed dynamic field-matching technique makes use of wedge junctions for the abutment of supraclavicular and HN IMRT fields. The supraclavicular field was shaped with a multileaf collimator (MLC), which was orientated such that the leaves traveled along the superoinferior direction. The leaves that defined the superior field border moved continuously during treatment from 1.5 cm below to 1.5 cm above the conventional match line to generate a 3-cm-wide wedge-shaped junction. The HN IMRT fields were optimized by taking into account the dose contribution from the supraclavicular field to the junction area, which generates a complementary wedge to produce a smooth junction in the abutment region. This technique was evaluated on a polystyrene phantom and 10 HN cancer patients. Treatment plans were generated for the phantom and the 10 patients. Dose profiles across the abutment region were measured in the phantom on films. For patient plans, dose profiles that passed through the center of the neck lymph nodes were calculated using the proposed technique and the SIHB technique, and dose uniformity in the abutment region was compared. Field mismatches of +/- 1 mm and +/- 2 mm because of imperfect jaw/MLC calibration were simulated, and the resulting dose inhomogeneities were studied for the two techniques with film measurements and patient plans. Three-dimensional volumetric doses were analyzed, and equivalent uniform doses (EUD) were computed. The effect of field mismatches on EUD was compared for the two match techniques. RESULTS: For a perfect jaw/MLC calibration, dose profiles for the 10 patients in the 3-cm match zone had an average inhomogeneity range of -1.6% to +1.6% using the dynamic-matching technique and -3.7% to +3.8% according to the SIHB technique. Measurements showed that dose inhomogeneities that resulted from 1-mm and 2-mm jaw/MLC calibration errors were reduced from as large as 27% and 45% with the SIHB technique to less than 2% and 5.7% with the dynamic technique, respectively. For -1-mm, -2-mm, +1-mm, and +2-mm jaw/MLC calibration errors, respectively, treatment plans for the 10 patients yielded average dose inhomogeneities of -5.9%, -3.0%, +2.7%, and +5.8% with the dynamic technique as compared to -22.8%, -11.1%, +9.8%, and +22.1% with the SIHB technique. Calculation based on a dose-volume histogram (DVH) showed that the SIHB technique resulted in larger changes in EUD of the PTV in the junction area than did the dynamic technique. CONCLUSION: Compared with the conventional SIHB technique, the dynamic field-matching technique provides superior dose homogeneity in the abutment region between the supraclavicular and HN IMRT fields. The dynamic feathering mechanism substantially reduces dose inhomogeneities that result from imperfect jaw/MLC calibration. In addition, isocenter location in the dynamic field-matching technique can be chosen for reproducible patient setup and for adequate IMRT field size rather than being dictated by the match position. It also allows angling of the supraclavicular field to reduce the volume of healthy lung irradiated, which is impractical with the SIHB technique. In principle, this technique should be applicable to any treatment site that requires the abutment of static and intensity-modulated fields.

Calibration↗