PubMed HealthSearch

PubMed · 8738899

How does positive end-expiratory pressure decrease CO2 elimination from the lung?

Abstract

Six chloralose-urethane anesthetized dogs (23 +/- 2 kg) underwent median thoracotomy (open pleural spaces) and constant mechanical ventilation with O2. We conducted measurements at baseline and during 25 min of ventilation with 3.3 cmH2O positive end-expiratory pressure (PEEP3) or 10.7 cmH2O PEEP (PEEP 11), including breath-by-breath values in the first 2 min after PEEP began. PEEP 11 immediately decreased pulmonary CO2 elimination per breath (VCO2,br, digital integration and multiplication of exhaled flow and FCO2) from 8.4 +/- 2.0 to 4.5 +/- 1.6 ml (P < 0.05) by significantly decreasing alveolar ventilation (VA) (29% increase in anatomical dead space (VDana) and generation of high VA/Q regions) and by decreasing alveolar PCO2 (PACO2) from 42.5 +/- 3.5 to 35.9 +/- 3.5 Torr (decreased CO2 transfer to the lung as electromagnetic aortic cardiac output (QT) decreased by 51%). The immediate dilution of alveolar gas and PACO2 by fresh gas as PEEP increased functional residual capacity by 1152 +/- 216 ml was offset by simultaneous decreased expiratory volume and, hence, CO2 accumulation. Compared to baseline, the 17% reduction in VCO2,br was sustained at 25 min after addition of PEEP 11 because VA remained depressed. Then, VCO2,br could only be restored to baseline if PACO2 sufficiently increased. However, CO2 transport was still in unsteady state at 25 min of PEEP. Peripheral tissue retention of CO2 and the significant increase in mixed venous PCO2 (PVCO2, 62.4 +/- 6.2 Torr) were not enough to normalize CO2 transfer to the lung and to sufficiently increase PACO2, especially during the continued depression in QT that occurred at higher PEEP. The sustained decrease in VCO2,br during PEEP was not mirrored by changes in end-tidal PCO2 (PETCO2).

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

P H Breen, B Mazumdar. 1996. How does positive end-expiratory pressure decrease CO2 elimination from the lung?. https://doi.org/10.1016/0034-5687(95)00089-5

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Intramuscular atropine sulfate in children: comparison of injection sites.

In children undergoing inhaled induction of anesthesia with halothane who suffer bradycardia, submental glossal injection of atropine may result in more rapid onset of vagolysis than traditional intramuscular sites. We compared the intervals between injection and onset of heart rate acceleration (tHR increases) after intramuscular injection of atropine into the deltoid, vastus lateralis, and glossa in children between 1 mo and 10 yr of age scheduled for elective surgery. The tHR increases was determined by measuring the interval between atropine injection and the time point at which the slope of the heart rate curve initially became positive. To ensure that the drug had taken effect before surgical stimulation, heart rate observation was continued until it increased at least 5% above baseline with evidence of continuing acceleration. Anesthesia was induced in all subjects by mask with nitrous oxide and halothane. After tracheal intubation, constant inspired concentrations of the anesthetics were administered for 3 min. While heart rate was monitored, atropine (0.02 mg/kg) was injected into one of the three sites. Each patient's end-tidal anesthetic concentrations were recorded, and minimum alveolar anesthetic concentrations (MAC) were subsequently calculated and adjusted for age. The tHR increases was recorded and averaged for each group. The study groups did not differ by age, weight, end-tidal anesthetic concentrations, age-adjusted MAC, or heart rate at the time atropine was administered. After submental glossal injection (n = 11), tHR increases increase was fastest (3.0 +/- 1.1 min) and was significantly faster than that found with deltoid injection (n = 16; 4.4 +/- 1.1 min) or vastus lateralis injection (n = 8; 6.4 +/- 2.4 min) (P < 0.05 compared with both). The tHR increases also differed significantly between the deltoid and the vastus lateralis (P < 0.05). We conclude that submental glossal injection of atropine results in a more rapid onset of vagolysis than injection at traditional intramuscular sites.

Anesthesia, Inhalation

Comparison of tests for detecting leaks in the low-pressure system of anesthesia gas machines.

Small leaks in the low-pressure system (LPS) of the anesthesia gas machine can cause hypoxia or patient awareness. We sought to determine the relative sensitivities of the various tests recommended for detecting LPS leaks before anesthesia. Special adapters were fashioned to create leaks of six different sizes in the LPS that were equivalent to the following: a single 25-, 22-, 20-, or 15-gauge needle, two 15-gauge needles, or a 2.5-mm endotracheal tube connector. With each leak condition, five different leak tests were performed on three each of the following machines: Ohmeda Modulus I, Ohmeda Modulus II-Plus, and North American Dräger Narkomed (2A, 3 and 4), for a total of 54 leaks to be detected for each leak test (3 x 3 x 6). The number of leaks detected with each test was compared by Fisher's exact test, P < 0.05 being considered significant. Only the negative pressure leak test detected all 54 leaks, a significant difference from the positive pressure test, which detected the least number of leaks, 28 (P < 0.05). Some leak tests are more suitable for specific anesthesia machines. Adoption of the negative pressure test as a universal LPS leak test may prevent the risks associated with using the wrong test for the particular anesthesia machine: hypoxic gas or patient awareness.

Anesthesia, Inhalation