PubMed HealthSearch

PubMed · 8894483

Oscillatory insulin secretion: a variable phenotypic marker.

Abstract

Oscillatory secretion of endocrine hormones is a widely recognized phenomenon. In man, as well as other species (dog, monkey), during the basal state insulin secretion is oscillatory and, on average, regular with a 13-min periodicity. In NIDDM there is a loss of regular oscillatory activity, being shorter in duration and irregular in nature. First-degree relatives of NIDDM subjects with normoglycaemia and obese normal subjects also exhibit this change, reverting to the regular oscillatory characteristic following weight loss in the latter group. The regular insulin secretory oscillations seen in the fasting stage in normal subjects are completely lost by raising the basal glucose concentration only marginally to about 6 mmol l-1. Thus, regular oscillations reflect a 'contented' beta-cell. Also, in states of hyperglycaemia, pulsatile exogenous insulin is more effective than continuous administration. Additional studies indicate that it is the periodicity of the insulin secretory oscillations and the rate of rise of the first phase insulin secretion in response to a glucose challenge which are the main candidates for successful signalling. Irregular oscillations of insulin can be used as an early marker of beta-cell under stress, but not as a fixed phenotypic marker.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

D R Matthews. 1996. Oscillatory insulin secretion: a variable phenotypic marker.. https://pubmed.ncbi.nlm.nih.gov/8894483/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Circadian and ultradian clock-controlled rhythms in unicellular microorganisms.

The time structure of a biological system is at least as intricate as its spatial structure. Whereas we have detailed information about the latter, our understanding of the former is still rudimentary. As techniques for monitoring intracellular processes continuously in single cells become more refined, it becomes increasingly evident that periodic behaviour abounds in all time domains. Circadian timekeeping dominates in natural environments. Here the free-running period is about 24 h. Circadian rhythms in eukaryotes and prokaryotes allow predictive matching of intracellular states with environmental changes during the daily cycles. Unicellular organisms provide excellent systems for the study of these phenomena, which pervade all higher life forms. Intracellular timekeeping is essential. The presence of a temperature-compensated oscillator provides such a timer. The coupled outputs (epigenetic oscillations) of this ultradian clock constitute a special class of ultradian rhythm. These are undamped and endogenously driven by a device which shows biochemical properties characteristic of transcriptional and translational elements. Energy-yielding processes, protein turnover, motility and the timing of the cell-division cycle processes are all controlled by the ultradian clock. Different periods characterize different species, and this indicates a genetic determinant. Periods range from 30 min to 4 h. Mechanisms of clock control are being elucidated; it is becoming evident that many different control circuits can provide these functions.

Activity Cycles

Lymph flow pattern in the intact thoracic duct in sheep.

1. To study the lymph flow dynamics in the intact thoracic duct, we applied an ultrasound transit-time flow probe in seven anaesthetized and four unanaesthetized adult sheep (approximately 60 kg). In unanaesthetized non-fasting animals we found that lymph flow in the thoracic duct was always regular pulsatile (pulsation frequency, 5.2 +/- 0.8 min-1) with no relation to heart or respiratory activity. At baseline the peak level of the thoracic duct pulse flow was 11.6-20.7 ml min-1 with a nadir of 0-3.6 ml min-1. Mean lymph flow was 5.4 +/- 3.1 ml min-1. The flow pattern of lymph in the thoracic duct was essentially the same in the anaesthetized animals. 2. In both the anaesthetized and unanaesthetized animals, the lymph flow response to a stepwise increase in the outflow venous pressure showed interindividual variation. Some were sensitive to any increase in outflow venous pressure, but others were resistant in that lymph flow did not decrease until outflow venous pressure was increased to higher levels. This resistance was also observed in the high lymph flow condition produced by fluid infusion in the anaesthetized animal and mechanical constriction of the caudal vena cava in the unaesthetized animals. Pulsation frequency of the thoracic duct flow initially increased and then decreased with a stepwise increase in the outflow venous pressure. This initial increase might be a compensatory response to maintain lymph flow against elevated outflow venous pressure. 3. To test the effect of long-term outflow venous pressure elevation in unanaesthetized sheep, outflow venous pressure was increased by inflation of a cuff around the cranial vena cava for 1, 5 or 25 h. The cuff was inflated to a level where lymph flow was reduced. Lymph flow remained low or decreased further during the entire cuff-inflation period. We calculated the lymph debt caused by the outflow venous pressure elevation and the amount 'repaid' when venous pressure returned to normal. Lymph debt for 25 h was 6400 ml but only 200 ml was repaid. Since we observed no visible oedema formation in the lower body of the sheep, the non-colloidal components of the lymph must have been reabsorbed into the bloodstream, most likely in the lymph nodes.

Activity Cycles

Voltammetric detection of nitric oxide (NO) in the rat brain: its variations throughout the sleep-wake cycle.

A sensor allowing the specific detection of nitric oxide (NO) is reported. Together with differential pulsed voltammetry, it allows the detection of a 650 mV signal either in NO solutions or in the rat frontal cortex. The intraperitoneal (i.p.) administration of a NO donor (S-nitrosoglutathione, 20 mg/kg i.p.) increases the signal height (+30%) while that of a nitric oxide synthase (NOS) inhibitor like L-nitro-arginine-p-nitro-anilide (100 mg/kg i.p.), produces its complete disappearance in the cortex of anesthetized rats. These results suggest that the 650 mV signal might be NO-dependent. Some other NOS inhibitors have been found either inefficient (L-nitro-arginine-methyl-ester) or partially efficient (7-nitro-indazole) on the signal height. In freely moving rats, also equipped with polygraphic electrodes, the signal measured in the frontal cortex exhibits the highest height during waking. It decreases during slow-wave sleep (-6%) and paradoxical sleep (-9%).

Activity Cycles