XYZ data interpreted by a 12-lead computer program using the derived electrocardiogram.

Abstract

The 12-lead electrocardiogram (ECG) derived from the Frank xyz signals was compared with the conventional 12-lead ECG using the Telemed computer system. In 100 cases studied. Telemed's interpretations were essentially similar in 77, but substantially different in 23. In the 23 cases, interpretations of the derived tracings tended to be more accurate in 14 cases, and less accurate in four cases. In the diagnosis of infarction the probability that the interpretation of the derived tracing will be correct more often was 90%. The better performance may have been related to closer agreement with the vectorcardiogram (VCG). As a substitute for the conventional ECG, the derived ECG offers the prospect of a computerized system that is more practical and more versatile than most currently used systems.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

G E Dower, H B Machado. 1979. XYZ data interpreted by a 12-lead computer program using the derived electrocardiogram.. https://doi.org/10.1016/s0022-0736(79)80058-8

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Electrocardiographic detection of left ventricular hypertrophy by the simple QRS voltage-duration product.

OBJECTIVES: The object of this study was to assess the hypothesis that the product of QRS voltage and duration, as an approximation of the time-voltage integral of the QRS complex, can improve the electrocardiographic (ECG) identification of left ventricular hypertrophy. BACKGROUND: Electrocardiographic identification of left ventricular hypertrophy has been limited by the poor sensitivity of standard voltage criteria. However, increases in left ventricular mass can be more closely related to increases in the time-voltage integral of the summed left ventricular dipole than to changes in voltage or QRS duration alone. METHODS: Antemortem ECGs were compared with left ventricular mass at autopsy in 220 patients. There were 95 patients with left ventricular hypertrophy, defined by left ventricular mass index > 118 g/m2 in men and > 104 g/m2 in women. The voltage-duration product was calculated as the product of QRS duration and Cornell voltage (Cornell product) and the 12-lead sum of QRS voltage (12-lead product). RESULTS: At partitions with a matched specificity of 95%, each voltage-duration product significantly improved sensitivity for the detection of left ventricular hypertrophy when compared with simple voltage criteria alone (Cornell product 51% [48 of 95] vs. Cornell voltage 36% [34 of 95], p < 0.005 and 12-lead product 45% [43 of 95] vs. 12-lead voltage 31% [30 of 95], p < 0.001). Sensitivity of both the Cornell product and 12-lead product was significantly greater than that found for QRS duration alone (28%, 27 of 95, p < 0.005) and the Romhilt-Estes point score (27%, 26 of 95, p < 0.005), and compared favorably with the sensitivity of the complex Cornell multivariate score (44%, 42 of 95, p = NS). Comparison of receiver operating characteristic curves demonstrated that improved performance of the voltage-duration products for the detection of left ventricular hypertrophy was independent of test partition selection. In addition, test performance of the voltage-duration products was not significantly affected by the presence or absence of a bundle branch block. CONCLUSIONS: These data suggest that the simple product of either Cornell or 12-lead voltage and QRS duration can identify left ventricular hypertrophy more accurately than can voltage or QRS duration criteria alone and may approach or exceed the performance of more complex multiple regression analyses.

Bundle-Branch Block

Effects of simulated left bundle branch block on QRST time-integral values of 12-lead electrocardiograms in patients with and without prior anterior wall myocardial infarction.

The effects of right ventricular pacing, which simulated left bundle branch block (BBB), on QRST time-integral values of 12-lead electrocardiograms (ECGs) were examined, and the clinical usefulness of QRST values for estimating the severity of left ventricular wall motion abnormalities due to a prior anterior wall myocardial infarction (MI) in the setting of left BBB were evaluated. Digitized ECGs were recorded during normal sinus rhythm and simulated left BBB in 38 patients (24 with and 14 without prior anterior wall MI). QRST values were calculated in each lead point of 12-lead ECGs. Data from 608 normal subjects were used as control values; the mean +/- 2 SD of these values was regarded as the normal range. The parameter sigma DE was defined as the sum of the differences between the normal mean QRST value and the QRST values of a given patient in leads where the QRST value was less than the normal range. The correlation coefficient of sigma DE for the 2 activation sequences was highly significant. Although small but significant changes were seen in QRST values in leads I, II, III, aVR, aVF and V1 during simulated left BBB, left precordial leads showed no significant changes in QRST values. A criterion of sigma DE > 40 mV.ms for detecting an anterior wall MI showed a sensitivity of 88%, a specificity of 93%, and a diagnostic accuracy of 89%. The sigma DE was significantly (p < 0.001) correlated with the asynergy index calculated from left ventriculograms.(ABSTRACT TRUNCATED AT 250 WORDS)

Bundle-Branch Block