Interactive edgewise mechanisms: form and function comparison with conventional edgewise brackets.

Abstract

As the frequency of use of the interactive twin (I-twin) edgewise mechanisms and techniques become increasingly prevalent, it is important to consider how they compare with conventional twin (c-twin) edgewise bracket systems. Optimum intrabracket and interbracket forces in I-twins balance with capillary blood pressures. An unbiased, experimental in vitro, scanning electromicroscopy and in vivo clinical investigation of 83 patients was conducted to compare the frictional resistance of three different I-twin bracket systems, type A (Sigma, American Orthodontics), type B (Interactwin, Ormco Corp.), and type C (Damon, A-company) with three c-twins counterparts respectively types D, E, and F. The three interactive twin brackets were each self-seating by an integrated arm component and made significant incremental improvements to the conventional twins in three different ways. First, the I-twin types reduced frictional resistance by using arm engagement with a lower coefficient of friction and a reduced seating force against the arch wire. The reduced seating force friction produced initially small interbracket arch wire deflections for biocompatible tooth movement and, combined with a wide twin bracket, produced accurate rotation corrections. Reduced friction within the I-twin bracket consequently permitted the effective use of light forces for flowing biomechanics that maximized anchorage. In evaluating friction, two distinctly different interaction forces acting to seat the arch wire were also identified. Type A demonstrated active interaction with round arch wires that resulted in a low functional seating force responsible for early and complete tooth control in comparison to the high seating force of c-twins. Types B and C both showed passive interaction with seating force friction approximately equal to zero that required large rectangular dimension arch wires for full bracket expression. Second, a significant reduction in the time taken to change arch wires was found, improving clinical time management. Third, I-twins assisted bracket placement with both center-slot identification markers and coordinated bracket and bonding pad reference planes in three dimensions. In addition, they improved bracket hygiene compared with c-twins by minimizing the use of plaque-retentive conventional ligatures. Despite the reduced elastomer use, experimental and clinical results showed I-twins effectively conserved the traditional four tie-wing design for ease of colored elastomer placement where an increase in friction for anchorage was selectively required and to enhance patient acceptance and motivation. Finally, interactive twins could be used by the practitioner as conventional twins without the interactive arms making them fail-safe.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

J C Voudouris. 1997. Interactive edgewise mechanisms: form and function comparison with conventional edgewise brackets.. https://doi.org/10.1016/s0889-5406(97)70208-7

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

The effect of excessive tibial torsion on the capacity of muscles to extend the hip and knee during single-limb stance.

Excessive tibial torsion, a rotational deformity about the long axis of the tibia, is common in patients with cerebral palsy who walk with a crouch gait. Previous research suggests that this deformity may contribute to crouch gait by reducing the capacity of soleus to extend the knee; however, the effects of excess external torsion on the capacity of other muscles to extend the stance limb during walking are unknown. A computer model of the musculoskeletal system was developed to simulate a range of tibial torsion deformities. A dynamic analysis was then performed to determine the effect of these deformities on the capacity of lower limb muscles to extend the hip and knee at body positions corresponding to the single-limb stance phase of a normal gait cycle. Analysis of the model confirmed that excessive external torsion reduces the extension capacity of soleus. In addition, our analysis revealed that several important muscles crossing the hip and knee are also adversely affected by excessive tibial torsion. With a tibial torsion deformity of 30 degrees , the capacities of soleus, posterior gluteus medius, and gluteus maximus to extend both the hip and knee were all reduced by over 10%. Since a tibial torsion deformity reduces the capacity of muscles to extend the hip and knee, it may be a significant contributor to crouch gait, especially when greater than 30 degrees from normal, and thus should be considered by clinicians when making treatment decisions.

Biomechanical Phenomena↗

Predicting the subject-specific primary stability of cementless implants during pre-operative planning: preliminary validation of subject-specific finite-element models.

Pre-operative planning help the surgeon in taking the proper clinical decision. The ultimate goal of this work is to develop numerical models that allow the surgeon to estimate the primary stability during the pre-operative planning session. The present study was aimed to validate finite-element (FE) models accounting for patient and prosthetic size and position as planned by the surgeon. For this purpose, the FE model of a cadaveric femur was generated starting from the CT scan and the anatomical position of a cementless stem derived by a skilled surgeon using a pre-operative CT-based planning simulation software. In-vitro experimental measurements were used as benchmark problem to validate the bone-implant relative micromotions predicted by the patient-specific FE model. A maximum torque in internal rotation of 11.4 Nm was applied to the proximal part of the hip stem. The error on the maximum predicted micromotion was 12% of the peak micromotion measured experimentally. The average error over the entire range of applied torques was only 7% of peak measurement. Hence, the present study confirms that it is possible to accurately predict the level of primary stability achieved for cementless stems using numerical models that account for patient specificity and surgical variability.

Biomechanical Phenomena↗

Experimental validation of intact and implanted distal femur finite element models.

Four finite element (FE) models of intact and distal femur of knee replacements were validated relative to measured bone strains. FE models of linear tetrahedrons were used. Femoral replacements with cemented stemless, cemented and noncemented femoral stems of the PFC Sigma Modular Knee System were analyzed. Bone strains were recorded at ten locations on the cortex. The magnitude of the FE bone strains corresponded to the mean measured strains, with an overall agreement of 10%. Linear regression between the FE and mean experimental strains produced slopes between 0.94 and 1.06 and R(2) values between 0.92 and 0.99. RSME values were less than 12%. The FE models were able to adequately replicate the mechanical behavior of distal femur reconstructions.

Biomechanical Phenomena↗