PubMed Health⌕ Search

PubMed · 9244727

[The exercise test with atropine].

Abstract

BACKGROUND: Exercise testing remains the most accessible and widely used technique for the detection of coronary artery disease (CAD) and for the assessment of its severity. Clinical usefulness of the simple exercise test is limited by poor sensitivity and imperfect specificity. Many patients referred for diagnostic stress testing cannot achieve an adequate increase in heart rate due to lack of motivation, poor physical condition, or medications. Atropine increases the heart rate and therefore myocardial oxygen consumption, and might improve the diagnostic accuracy of exercise testing, either reducing the number of non-diagnostic examinations, or increasing the positivity of the test in patients with non severe coronary disease. METHODS: One-hundred-seventy-two consecutive patients (144 males and 28 females, age 58 +/- 8 years) with suspected coronary artery disease underwent exercise testing and coronary angiography. Exercise testing was considered positive in the presence of ST segment depression > or = 0.10 mV horizontal or downsloping, > or = 0.15 mV upsloping, or in the presence of ST elevation without Q waves. The test was considered negative in the absence of significant ST depression or elevation if the exercise heart rate was > 85% of age-predicted maximum, non-diagnostic if the heart rate was < 85%. In 148 patients (86%) coronary angiography showed CAD (> 70% luminal reduction in at least one major vessel), in 24 patients (14%) non significant CAD or angiographically normal coronary arteries (NoCAD). Exercise testing was positive in 134 patients (78%: 85% in CAD, 33% in NoCAD), negative in 13 patients (8%: 3% in CAD, 38% in NoCAD), non-diagnostic in 25 patients (14%; 12% in CAD, 29% in NoCAD). The sensitivity was 85%, specificity was 38%, and diagnostic accuracy 78%. In the 25 patients with non-diagnostic test (18 CAD, 7 NoCAD) the exercise was repeated 30-90 minutes later, immediately after i.v. injection of 1-2 mg of atropine, and was stopped at the same workload of the index test. RESULTS: The atropine-exercise test was well tolerated and accomplished in all cases. The maximal heart rate (139 +/- 11 vs 121 +/- 11) and the double product (25,308 +/- 4082 vs 22,166 +/- 3569) were significantly greater after atropine. The increase of the maximal heart rate improved the detection of the electrocardiographic signs of exercise-induced myocardial ischemia only in CAD patients. In the 18 CAD patients the atropine-exercise test was positive in 8, negative in 5, non-diagnostic in 5. In the 7 NoCAD patients the atropine-exercise test was positive in 1, negative in 6. The test remained non-diagnostic only in 3% of patients. The sensitivity of the test with atropine was 91%, specificity was 63%, and diagnostic accuracy 87%. CONCLUSIONS: The addition of atropine to exercise testing, which causes further chronotropic stress to the myocardium, is well tolerated and safe, and improves the diagnostic accuracy of the test for the detection of coronary artery disease in patients who cannot achieve an adequate exercise heart rate. The combination with atropine increases the utility and the cost-effectiveness of exercise testing.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

A Variola, R Albiero, B Dander, C Buonanno. 1997. [The exercise test with atropine].. https://pubmed.ncbi.nlm.nih.gov/9244727/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Conservative treatment of infantile hypertrophic pyloric stenosis with intravenous atropine sulfate does not replace pyloromyotomy.

Pyloromyotomy as described by Weber and Ramstedt has been the standard therapy for infantile hypertrophic pyloric stenosis since the 1960's and conservative therapy has been abandoned. The objective of this study was to test the effectiveness of systemic atropine applied intravenously for 7 days as a conservative therapeutic strategy and as an alternative to primary operation. Forty-two consecutive term infants with infantile hypertrophic pyloric stenosis were enrolled in the study over a period of 5 years. After confirmation of the diagnosis they all received intravenous atropine at a dose of 0.04 mg/(kg day) and increased by 0.01 mg/(kg day) up to 0.12 mg/(kg day), given as 6-8 single doses per/day. Nine pairs of parents requested that their child should be operated before completing the 7 days of medical therapy. Surgery was necessary in 8 of the remaining 33 infants (24,.2%) who did not improve after 7 days of conservative treatment. Successful treatment with i.v. atropine sulfate was achieved only in 25/33 term infants at an average maximal dose of 0.11 mg/(kg day), without any major side effects. Intravenous atropine sulfate has been considered as a potential alternative therapeutic strategy in the treatment of infantile hypertrophic pyloric stenosis. Clinical improvement however was often not seen before the 6th or 7th day of intravenous treatment. A success rate for the conservative approach of only 75% at day 7 in our study does not favour atropine therapy, in view of success rates above 95% with surgical repair.

Atropine↗

Impurity profiling of atropine sulfate by microemulsion electrokinetic chromatography.

An oil-in-water microemulsion electrokinetic chromatography (MEEKC) method has been developed and validated for the determination of atropine, its major degradation products (tropic acid, apoatropine and atropic acid) and related substances from plants material (noratropine, 6-hydroxyhyoscyamine, 7-hydroxyhyoscyamine, hyoscine and littorine). Separation of atropine and all impurities was optimized by varying the voltage, the nature of the oil droplet and the buffer, as well as the organic modifier (methanol, 2-propanol or acetonitrile) and the surfactant type and concentration. The optimum O/W microemulsion background electrolyte (BGE) solution consists of 0.8% (w/w) octane, 6.62% (w/w) 1-butanol, 2.0% (w/w) 2-propanol, 4.44% (w/w) SDS and 86.14% (w/w) 10 mM sodium tetraborate buffer pH 9.2. In order to shorten the analysis time a voltage gradient was applied. The validation was performed with respect to specificity, linearity, range, limit of quantification and detection, precision, accuracy and robustness. The established method allowed the detection and determination of atropine sulfate related substances at impurity levels given in the European Pharmacopoeia. Good agreement was obtained between the established MEEKC method and the traditional RP-HPLC method.

Atropine↗