PubMed Health⌕ Search

PubMed · 9263094

Lung mechanical behavior during one-lung ventilation.

Abstract

OBJECTIVE: Switching from two-lung to one-lung ventilation would be expected to have large effects on lung mechanical properties, and these effects may depend on tidal volume and respiratory frequency. These changes in lung mechanics with one-lung ventilation may be similar to pulmonary edema. Deteriorating lung mechanics during pulmonary edema have been attributed to a loss of ventilated lung units. Therefore, changes in lung mechanics caused by one-lung ventilation were measured and compared with those previously seen during pulmonary edema. DESIGN: Prospective study. SETTING: Research laboratory. INTERVENTIONS: After induction of anesthesia, beagle dogs' tracheas were intubated with an endotracheal tube with a bronchial blocker (Univent System Corp, Tokyo, Japan) to apply one-lung ventilation. The proper position of the bronchial blocker during one-lung ventilation was confirmed with a fiberoptic bronchoscope. MEASUREMENTS AND MAIN RESULTS: Lung elastance (EL) and resistance (RL) were calculated from measurements of airway pressure, esophageal pressure, and airway flow in five anesthetized, paralyzed dogs during sinusoidal forcing at a constant mean airway pressure of 10 cmH2O in a wide range of breathing frequencies (0.2 to 1.0 Hz in intervals of 0.2) and tidal volumes (50, 100, 200, and to 300 mL). Measurements were made before and after the left mainstem bronchus was occluded with the bronchial blocker. During ventilation of both lungs, EL and RL depended relatively little on frequency, and both EL and RL were independent of tidal volume. During one-lung ventilation, EL doubled and, at most frequencies, RL increased; frequency dependences were not increased, and no dependence on tidal volume was observed. CONCLUSIONS: The lack of tidal volume dependence in EL and lack of large-frequency dependence in RL during one-lung ventilation are inconsistent with changes induced by severe pulmonary edema. Although decreases in ventilatable lung volume may contribute to increases in lung elastance, other characteristics of mechanical behavior during one-lung ventilation differ from those of pulmonary edema; therefore, other additional mechanisms must be involved in determining lung mechanical properties during severe pulmonary edema.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

G M Barnas, J Sprung, D Choi, R Kahn. 1997. Lung mechanical behavior during one-lung ventilation.. https://doi.org/10.1016/s1053-0770(97)90013-6

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Correction of compliance and resistance altered by endotracheal tube leaks and non-linear pressure/volume-relationships.

Measurements of lung compliance (C) and resistance (R) are influenced by endotracheal tube leaks (ETTL) as well as non-linear pressure/volume relationships (P/V relationship). To keep C and R reliable, we developed an algorithm to mathematically correct inspiratory and expiratory volume (V) and flow. In this study, a ventilated lung model for non-linear P/V relationship with adjustment of an increasing ETTL was studied. In addition, the recordings (airway pressure, flow, and volume) of 21 infants (median weight: 1,220 g, range: 640-2,160 g, with a median leak size of 32%, range: 24-56%) were investigated. C and R were calculated continuously from the recordings of flow, volume, and airway pressure over time according to the changing volume. A method especially developed for the analysis of non-linear pressure-volume-relationship (APVNL) was employed. C and R affected by leaks were corrected applying the newly developed mathematical algorithm and compared with measurements without leakage. C could be corrected up to a leak of 80% and R up to 55% leak at half tidal V for the model with non-linear P/V-R. C and R without leak and after leak correction did not differ significantly in all infants where the APVNL method was applied (P > 0.05).

Airway Resistance↗

Parenchymal tethering, airway wall stiffness, and the dynamics of bronchoconstriction.

We do not yet have a good quantitative understanding of how the force-velocity properties of airway smooth muscle interact with the opposing loads of parenchymal tethering and airway wall stiffness to produce the dynamics of bronchoconstriction. We therefore developed a two-dimensional computational model of a dynamically narrowing airway embedded in uniformly elastic lung parenchyma and compared the predictions of the model to published measurements of airway resistance made in rats and rabbits during the development of bronchoconstriction following a bolus injection of methacholine. The model accurately reproduced the experimental time-courses of airway resistance as a function of both lung inflation pressure and tidal volume. The model also showed that the stiffness of the airway wall is similar in rats and rabbits, and significantly greater than that of the lung parenchyma. Our results indicate that the main features of the dynamical nature of bronchoconstriction in vivo can be understood in terms of the classic Hill force-velocity relationship operating against elastic loads provided by the surrounding lung parenchyma and an airway wall that is stiffer than the parenchyma.

Airway Resistance↗

Use of dynamic compliance for open lung positive end-expiratory pressure titration in an experimental study.

OBJECTIVE: We tested whether the continuous monitoring of dynamic compliance could become a useful bedside tool for detecting the beginning of collapse of a fully recruited lung. DESIGN: Prospective laboratory animal investigation. SETTING: Clinical physiology research laboratory, University of Uppsala, Sweden. SUBJECTS: Eight pigs submitted to repeated lung lavages. INTERVENTIONS: Lung recruitment maneuver, the effect of which was confirmed by predefined oxygenation, lung mechanics, and computed tomography scan criteria, was followed by a positive end-expiratory pressure (PEEP) reduction trial in a volume control mode with a tidal volume of 6 mL/kg. Every 10 mins, PEEP was reduced in steps of 2 cm H2O starting from 24 cm H2O. During PEEP reduction, lung collapse was defined by the maximum dynamic compliance value after which a first measurable decrease occurred. Open lung PEEP according to dynamic compliance was then defined as the level of PEEP before the point of collapse. This value was compared with oxygenation (Pao2) and CT scans. MEASUREMENTS AND MAIN RESULTS: Pao2 and dynamic compliance were monitored continuously, whereas computed tomography scans were obtained at the end of each pressure step. Collapse defined by dynamic compliance occurred at a PEEP of 14 cm H2O. This level coincided with the oxygenation-based collapse point when also shunt started to increase and occurred one step before the percentage of nonaerated tissue on the computed tomography exceeded 5%. Open lung PEEP was thus at 16 cm H2O, the level at which oxygenation and computed tomography scan confirmed a fully open, not yet collapsed lung condition. CONCLUSIONS: In this experimental model, the continuous monitoring of dynamic compliance identified the beginning of collapse after lung recruitment. These findings were confirmed by oxygenation and computed tomography scans. This method might become a valuable bedside tool for identifying the level of PEEP that prevents end-expiratory collapse.

Airway Resistance↗